13. MANUAL AUTO OPERATION (Indoor unit body operation)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table 6.
If the remote control is lost or battery power dissipated, this function will work without the remote
control.
OPERATION MODE Auto changeover
FAN CONT. MODE Auto
TIMER MODE Continuous
SETTING TEMP. 75°F(24°C)
SETTING LOUVER Standard
SWING OFF
(Table 6)
(No timer setting available)
15. COMPRESSOR PREHEATING
01-16
14. FORCED COOLING OPERATION
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table 7.
Manual auto operation
When the outdoor heat exchanger temperature is lower than Operation temperature (Refer to Table 8)
and the heating operation has
been stopped for 3 hours, power is applied to the compressor and
the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started, and when the outdoor temperature rises to Release temperature or greater,
preheating
is over.
(Table 8 : Preheating Operation / Release Temperature)
Before 24 hour After 24 hour
Operation
temperature
Operation
temperature
Release
temperature
Release
temperature
AOU24RML
AOU36RML
37.4°F
(3°C)
44.6°F
(7°C)
32°F
(0°C)
39.2°F
(4°C)
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING
(Table 7)
Forced cooling operation
Cooling
Hi
Horizontal
OFF
Room Temp is not controlled
-