8. Safety devices
Type of
protection
Protection form
Model
ASUG09LZAS ASUG12LZAS ASUG15LZAS
Circuit
protection
Current fuse (PCB*) 250 V, 3.15 A
Fan motor
protection
Thermal
protector
program
Activate
257±18 °F (125±10 °C)
Fan motor stop
Reset
212±18 °F (100±10 °C)
Fan motor restart
*PCB: Printed Circuit Board
- 20 -