EasyManuals Logo

Fujitsu AOUG48LMAS1 User Manual

Fujitsu AOUG48LMAS1
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
03-12
Troubleshooting 7
Connection unit number error
(Indoor unit in wired remote control system)
Detective actuators:
Wired remote control (2-Wire)
Indoor unit controller PCB circuit
Detective details:
When number of connecting indoor units
are out of specified rule.
Indicate or Display:
Indoor unit
Operation lamp: 2 times Flash,
Timer lamp : 9 times Flash
Wired remote control
Error code : [E : 29]
n
: n times blinking
: Light ON: Light OFF
Mode Error
2 5
15
Outdoor unit (AOUG36/48LMAS1)
A
B F
E
D
C
Forecast of cause :
1. Wrong wiring / number of indoor units, remote control in RC-group
2. Indoor unit controller PCB defective
Check Point 1 : Wire installation
Wrong number of connecting indoor unit
Check Point 2 : Check Indoor unit controller PCB
Check if controller PCB damage
Check if controller PCB and check the error
after setting remote control address