4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASUH09LMAS
AFR CFM 453
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
-15 -17 5.77 1.24 5.62 1.27 5.47 1.29 5.32 1.31 5.17 1.33
-5 -7 8.07 1.32 7.86 1.34 7.65 1.37 7.44 1.39 7.23 1.41
5 3 9.46 1.23 9.21 1.25 9.48 1.28 8.72 1.30 8.47 1.33
14 12 10.52 1.31 10.25 1.33 9.97 1.36 9.69 1.39 9.42 1.41
23 19 12.38 1.38 12.05 1.41 11.73 1.44 11.41 1.47 11.08 1.50
32 28 14.06 1.49 13.69 1.52 13.32 1.55 12.95 1.58 12.59 1.61
41 37 15.56 1.58 15.15 1.62 14.75 1.65 14.34 1.68 13.93 1.71
47 43 16.89 1.60 16.44 1.63 16.00 1.67 15.56 1.70 15.12 1.73
50 47 16.97 1.62 16.53 1.65 16.09 1.69 15.64 1.72 15.20 1.75
59 50 17.15 1.53 16.70 1.56 16.25 1.59 15.80 1.62 15.36 1.65
68 59 16.18 1.19 15.76 1.21 15.33 1.24 14.91 1.26 14.48 1.29
75 64 16.71 1.25 16.27 1.27 15.83 1.30 15.40 1.32 14.96 1.35
AFR
m
3
/h
770
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-26.1 -27.0 1.69 1.24 1.65 1.27 1.60 1.29 1.56 1.31 1.51 1.33
-20.6 -21.7 2.37 1.32 2.30 1.34 2.24 1.37 2.18 1.39 2.12 1.41
-15.0 -16.1 2.77 1.23 2.70 1.25 2.78 1.28 2.55 1.30 2.48 1.33
-10.0 -11.1 3.08 1.31 3.00 1.33 2.92 1.36 2.84 1.39 2.76 1.41
-5.0 -7.2 3.63 1.38 3.53 1.41 3.44 1.44 3.34 1.47 3.25 1.50
0.0 -2.2 4.12 1.49 4.01 1.52 3.90 1.55 3.80 1.58 3.69 1.61
5.0 2.8 4.56 1.58 4.44 1.62 4.32 1.65 4.20 1.68 4.08 1.71
8.3 6.1 4.95 1.60 4.82 1.63 4.69 1.67 4.56 1.70 4.43 1.73
10.0 8.3 4.97 1.62 4.84 1.65 4.71 1.69 4.58 1.72 4.45 1.75
15.0 10.0 5.03 1.53 4.90 1.56 4.76 1.59 4.63 1.62 4.50 1.65
20.0 15.0 4.74 1.19 4.62 1.21 4.49 1.24 4.37 1.26 4.25 1.29
24.0 18.0 4.90 1.25 4.77 1.27 4.64 1.30 4.51 1.32 4.38 1.35
¢
Model: ASUH12LMAS
AFR CFM 453
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
-15 -17 6.52 1.24 6.35 1.27 6.18 1.29 6.01 1.31 5.84 1.33
-5 -7 9.12 1.32 8.88 1.34 8.65 1.37 8.41 1.39 8.17 1.41
5 3 11.29 1.23 11.00 1.25 10.70 1.28 10.40 1.30 10.11 1.33
14 12 12.56 1.31 12.23 1.33 11.90 1.36 11.57 1.39 11.24 1.41
23 19 14.77 1.38 14.39 1.41 14.00 1.44 13.61 1.47 13.23 1.50
32 28 16.78 1.49 16.34 1.52 15.90 1.55 15.46 1.58 15.02 1.61
41 37 18.57 1.58 18.09 1.62 17.60 1.65 17.11 1.68 16.63 1.71
47 43 20.16 1.60 19.63 1.63 19.10 1.67 18.57 1.70 18.04 1.73
50 47 20.26 1.62 19.73 1.65 19.20 1.69 18.67 1.72 18.14 1.75
59 50 20.47 1.53 19.94 1.56 19.40 1.59 18.86 1.62 18.33 1.65
68 59 19.31 1.19 18.81 1.21 18.30 1.24 17.79 1.26 17.29 1.29
75 64 19.94 1.25 19.42 1.27 18.90 1.30 18.38 1.32 17.86 1.35
AFR
m
3
/h
770
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-26.1 -27.0 1.91 1.24 1.86 1.27 1.81 1.29 1.76 1.31 1.71 1.33
-20.6 -21.7 2.67 1.32 2.60 1.34 2.53 1.37 2.46 1.39 2.39 1.41
-15.0 -16.1 3.31 1.23 3.22 1.25 3.14 1.28 3.05 1.30 2.96 1.33
-10.0 -11.1 3.68 1.31 3.58 1.33 3.49 1.36 3.39 1.39 3.30 1.41
-5.0 -7.2 4.33 1.38 4.22 1.41 4.10 1.44 3.99 1.47 3.88 1.50
0.0 -2.2 4.92 1.49 4.79 1.52 4.66 1.55 4.53 1.58 4.40 1.61
5.0 2.8 5.44 1.58 5.30 1.62 5.16 1.65 5.02 1.68 4.87 1.71
8.3 6.1 5.91 1.60 5.75 1.63 5.60 1.67 5.44 1.70 5.29 1.73
10.0 8.3 5.94 1.62 5.78 1.65 5.63 1.69 5.47 1.72 5.32 1.75
15.0 10.0 6.00 1.53 5.84 1.56 5.69 1.59 5.53 1.62 5.37 1.65
20.0 15.0 5.66 1.19 5.51 1.21 5.36 1.24 5.22 1.26 5.07 1.29
24.0 18.0 5.85 1.25 5.69 1.27 5.54 1.30 5.39 1.32 5.23 1.35
- 9 -