01-16
21. POWERFUL OPERATION
The POWERFUL OPERATION functions by pressing POWERFUL button on the remote controller.
The indoor unit & outdoor unit will operate at maximum power as shown in Table22.
Release Condition is as follows.
[Cooling / Dry]
- Room tenperature < Setting temperature - 1.5°C or Operation time has passed 20 minutes.
COMPRESSOR FREQUENCY Maximum
FAN CONT. MODE Powerful
SETTING LOUVER Cooling/ Dry : 3, Heating : 5
(Table22)
Powerful operation
=
=
[Heating]
- Room tenperature > Setting temperature +1.5°C or Operation time has passed 20 minutes.