EasyManua.ls Logo

Fujitsu AOYG09KMTA User Manual

Fujitsu AOYG09KMTA
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Split type room air conditioner
Wall mounted type
Indoor unit Outdoor unit
CONTENTS
SPECIFICATIONS. . . . . . . . . . . . . . . . . . .
1
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .
3
REFRIGERANT SYSTEM DIAGRAM. . . .
6
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .
9
ERROR DETECTION . . . . . . . . . . . . . . . .
10
PCB CIRCUIT DIAGRAM . . . . . . . . . . . . .
12
PARTS (INDOOR UNIT) . . . . . . . . . . . . .
13
PARTS (OUTDOOR UNIT) . . . . . . . . . . .
21
33
ACCESSORIES . . . . . . . . . . . . . . . . . . .
ASYG07KMTA
ASYG09KMTA
ASYG12KMTA
ASYG14KMTA
AOYG07KMTA
AOYG09KMTA
AOYG12KMTA
AOYG14KMTA

Other manuals for Fujitsu AOYG09KMTA

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG09KMTA and is the answer not in the manual?

Fujitsu AOYG09KMTA Specifications

General IconGeneral
TypeAir conditioner outdoor unit
Ionizer-
Multi-splitNo
Product colorWhite
Compressor typeRotary
Gas hose diameter9.5 mm
Hose length (max)15 m
Inverter technologyYes
Liquid hose diameter6.35 mm
Refrigerating mediumR32
Air conditioner functionsCooling, Heating
Refrigerating medium weight600 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Hourly energy consumption (cooling)- kWh
Indoor unit noise level (high speed)- dB
Outdoor unit depth290 mm
Outdoor unit width663 mm
Outdoor unit height541 mm
Outdoor unit weight23000 g
Outdoor units quantity1
Outdoor unit noise level61 dB
Cooling airflow (outdoor unit)750 m³/h
Outdoor unit sound power level46 dB

Summary

SPECIFICATIONS

ELECTRICAL DATA

Details specifications for power supply, current, power consumption, EER, and COP for indoor and outdoor units.

PARTS

INDOOR UNIT PARTS

Lists and illustrates replaceable parts for the indoor unit, including assemblies and individual components.

OUTDOOR UNIT PARTS

Lists and illustrates replaceable parts for the outdoor unit, including assemblies and individual components.

DESCRIPTION OF EACH CONTROL OPERATION

COMPRESSOR CONTROL

Explains compressor frequency range, start-up control, and limitations based on outdoor temperature.

TIMER OPERATION CONTROL

Describes timer settings for wireless and wired remote controllers, including ON/OFF, Program, and Sleep timers.

DEFROST OPERATION CONTROL

CONDITION OF STARTING DEFROST OPERATION

Specifies the conditions related to outdoor heat exchanger temperature for initiating defrost operation.

CONDITION OF DEFROST OPERATION COMPLETION

Defines the conditions under which defrost operation is released, based on temperature or time.

OFF DEFROST OPERATION CONTROL

Describes automatic defrosting in heating mode when frost adheres to the outdoor heat exchanger.

VARIOUS PROTECTIONS

DISCHARGE GAS TEMPERATURE OVERRISE PREVENTION CONTROL

Details protection against high discharge gas temperature by reducing compressor frequency or stopping it.

TROUBLE SHOOTING

ERROR DISPLAY

Details error codes and corresponding indicator lamp patterns for indoor units and wired remote controllers.

TROUBLESHOOTING WITH ERROR CODE

Provides diagnostic steps for specific error codes related to communication, sensors, and PCB failures.

TROUBLESHOOTING WITH NO ERROR CODE

Guides for diagnosing issues like no power, no cooling/heating, or abnormal noise without specific error codes.

SERVICE PARTS INFORMATION

COMPRESSOR

Provides troubleshooting steps and checks for compressor issues like failure to start or abnormal noise.

APPENDING DATA

Related product manuals