8. COMPRESSOR CONTROL
01-09
1. OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the Table 11.
Cooling / Dry Heating
Minimum Maximum Minimum Maximum
84rps
90rps
90rps
89rps
14rps14rps
12rps
110rps
12rps
45rps 56rps
68rps
(Table 11 : Compressor frequency range)
2. OPEARTION FREQUENCY CONTROL AT NORMAL START UP
The compressor frequency soon after the start-up is controlled as shown in the Fig.10
(Fig.10 : Compressor control at start-up)
Time
Time Time Time
Time
(Frequency)
Frequency
Frequency
Frequency Frequency Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
Time
Time Time Time
Time
60sec
140sec 170sec 220sec 280sec 360sec 430sec
(Time)
77rps
84rps
Frequency
Frequency
Time
6
Time
7
Time
7
Frequency Frequency
Time
6
93rps 103rps
3. LIMITATION OF COMPRESSOR FREQUENCY BY OUTDOOR TEMPERATURE
The minimum compressor frequency is limited by outdoor temperature as shown in the Table12.
Over Under Over Under Over Under Over Under
Over Under Over Under Over Under Over Under
AO*G07/ 09KMTA
AO*G12KMTA
AO*G14KMTA
21rps 16rps 33rps 42rps
36rps28rps36rps 1rps
28rps
26rps
49rps33rps21rps 16rps 24rps
(Table12 : Limitation of Compressor Frequency)
38°C 19°C 10°C 0°C
[ Cooling/ Dry ]
AO*G07/ 09/ 12KMTA
AO*G14KMTA
16rps 16rps 30rps 43rps
37rps36rps1rps 1rps
18rps
15rps
19°C 5°C 0°C -15°C
[ Heating ]
AO*G07KMTA
AO*G09KMTA
AO*G12KMTA
AO*G14KMTA

Other manuals for Fujitsu AOYG09KMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG09KMTA and is the answer not in the manual?

Fujitsu AOYG09KMTA Specifications

General IconGeneral
TypeAir conditioner outdoor unit
Ionizer-
Multi-splitNo
Product colorWhite
Compressor typeRotary
Gas hose diameter9.5 mm
Hose length (max)15 m
Inverter technologyYes
Liquid hose diameter6.35 mm
Refrigerating mediumR32
Air conditioner functionsCooling, Heating
Refrigerating medium weight600 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Hourly energy consumption (cooling)- kWh
Indoor unit noise level (high speed)- dB
Outdoor unit depth290 mm
Outdoor unit width663 mm
Outdoor unit height541 mm
Outdoor unit weight23000 g
Outdoor units quantity1
Outdoor unit noise level61 dB
Cooling airflow (outdoor unit)750 m³/h
Outdoor unit sound power level46 dB

Related product manuals