11. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
11-1. Function settings by using remote controller
Some function settings can be changed on the remote controller. After confirming the setting pro-
cedure and the content of each function setting, select appropriate functions for your installation
environment.
¢
Setting procedure by using wireless remote controller
The function number and the associated setting value are displayed on the LCD of the remote
controller. Follow the instructions written in the local setup procedure supplied with the remote
controller, and select appropriate setting according to the installation environment.
Before connecting the power supply of the indoor unit, reconfirm following items:
Piping air tight test and vacuuming have been performed firmly.
There is no wiring mistake.
Then, connect the power supply of the indoor unit.
Entering function setting mode:
While pressing the POWERFUL button and TEMP. ( ) button simultaneously, press the RESET
button to enter the function setting mode.
STEP 1: Setting the remote controller custom code
Use the following steps to select the custom code of the remote controller. (Note that the air con-
ditioner cannot receive a custom code if the air conditioner has not been set for the custom code.)
The custom codes that are set through this process are applicable only to the signal in the func-
tion setting.
For details on how to set the custom codes through the normal process, refer to "Custom code
setting for wireless remote controller" on page 35.
1. Press the TEMP. (
) ( ) buttons to change the custom code be-
tween . Match the code on the display to the air
conditioner custom code. (Initially set to .) If the custom code
does not need to be selected, press the 10 °C HEAT button, and
proceed to STEP 2.
2. Press the MODE button and check that the indoor unit can receive
signals at the displayed custom code.
3. Press the 10 °C HEAT button to accept the custom code, and pro-
ceed to STEP 2.
4. After completing the function setting, be sure to disconnect the
power supply and then reconnect it.
- 29 -
WALL MOUNTED
ASYG07-14KMTA

Table of Contents

Other manuals for Fujitsu AOYG12KMTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG12KMTA and is the answer not in the manual?

Fujitsu AOYG12KMTA Specifications

General IconGeneral
TypeAir conditioner outdoor unit
Multi-splitNo
Product colorWhite
Gas hose diameter9.5 mm
Hose length (max)15 m
Inverter technologyYes
Liquid hose diameter6.35 mm
Refrigerating mediumR32
Air conditioner functionsCooling, Heating
Refrigerating medium weight700 g
Cooling capacity in watts (nominal)- W
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)-
AC input voltage230 V
Current (cooling)6.5 A
Current (heating)9 A
AC input frequency50 Hz
Design load (cooling)- kW
Hourly energy consumption (cooling)- kWh
Indoor unit noise level (high speed)- dB
Outdoor unit depth290 mm
Outdoor unit width663 mm
Outdoor unit height541 mm
Outdoor unit weight25000 g
Outdoor units quantity1
Outdoor unit noise level58 dB
Cooling airflow (outdoor unit)770 m³/h
Outdoor unit sound power level50 dB

Related product manuals