7. Additional charge calculation
7-1. Models:AOYG07LMCE and AOYG09LMCE
Refrigerant type R410A
Refrigerant amount g 700
¢ Refrigerant charge
Total pipe length m 15 or less 20 (Max.)
20 g/m
Additional charge g 0 100
7-2. Model:AOYG12LMCE
Refrigerant type R410A
Refrigerant amount g 850
¢ Refrigerant charge
Total pipe length m 15 or less 20 (Max.)
20 g/m
Additional charge g 0 100
7-3. Model:AOYG14LMCE
Refrigerant type R410A
Refrigerant amount g 1,050
¢ Refrigerant charge
Total pipe length m 15 or less 20 (Max.)
20 g/m
Additional charge g 0 100