7. Additional charge calculation
7-1. Model: AOYG18KLCA
Refrigerant type R32
Refrigerant amount g 850
¢ Refrigerant charge
Total pipe length m 15 or less 20 25 (Max.)
20 g/m
Additional charge g 0 100 200
7-2. Model: AOYG24KLCA
Refrigerant type R32
Refrigerant amount g 1,100
¢ Refrigerant charge
Total pipe length m 15 or less 20 25 30 (Max.)
20 g/m
Additional charge g 0 100 200 300