EasyManua.ls Logo

Fujitsu AOYG18KLCA - Outdoor Unit Safety Devices

Fujitsu AOYG18KLCA
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Safety devices
Type of protection Protection form
Model
AOYG18KLCA AOYG24KLCA
Circuit protection Current fuse (Main PCB)
250 V, 20 A 250 V, 25 A
250 V, 5 A
250 V, 3.15 A
Fan motor
protection
Terminal protection
program
Activate
100±15 °C
Fan motor stop
125±10 °C
Fan motor stop
Reset
95±10 °C
Fan motor restart
120±10 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
115 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
After 3 minutes
Compressor restart
- 42 -
11. Safety devices
OUTDOOR UNIT
AOYG18, 24KLTA
OUTDOOR UNIT
AOYG18, 24KLTA