Heating Capacity | 10.0 kW |
---|---|
Energy Efficiency Ratio (EER) | 3.21 |
Refrigerant | R32 |
Outdoor Unit Dimensions (W x H x D) | 900 x 830 x 330 mm |
Power Supply | 220-240V, 50Hz |
Outdoor Unit Noise Level | 55 dB(A) |
Type | Split Air Conditioner |
Lists various indoor unit types like Compact Cassette, Cassette, Slim Duct, Duct, Floor/Ceiling, Ceiling.
Lists outdoor unit models like AOYG72LRLA and AOYG90LRLA.
Provides detailed specifications for AUYG18LVLB, AUYG22LVLA, AUYG24LVLA.
Provides detailed specifications for AUYG30LRLE, AUYG36LRLE, AUYG45LRLA.
Provides detailed specifications for ARYG18LLTB.
Provides detailed specifications for ARYG22LMLA and ARYG24LMLA.
Provides detailed specifications for ABYG18LVTB, ABYG22LVTA, ABYG24LVTA.
Provides detailed specifications for ABYG30LRTE, ABYG36LRTE, ABYG45LRTA.
Provides detailed dimensional drawings for AUYG18LVLB, AUYG22LVLA, AUYG24LVLA.
Provides dimensional drawings for AUYG30LRLE, AUYG36LRLE, AUYG45LRLA.
Provides dimensional drawings for ARYG18LLTB.
Provides dimensional drawings for ARYG22LMLA, ARYG24LMLA, ARYG30LMLE, ARYG36LMLE, ARYG45LMLA.
Provides dimensional drawings for ABYG18LVTB, ABYG22LVTA, ABYG24LVTA.
Specifies required clearances for floor/ceiling type units.
Provides dimensional drawings for ABYG30LRTE, ABYG36LRTE, ABYG45LRTA.
Specifies required clearances for ceiling type units in different scenarios.
Provides wiring diagram for compact cassette indoor units.
Provides wiring diagram for cassette type indoor units.
Provides wiring diagram for slim duct type indoor units.
Provides detailed specifications for ARYG22LMLA and ARYG24LMLA.
Provides wiring diagram for floor/ceiling type indoor units.
Provides wiring diagram for ceiling type indoor units.
Provides fan performance curves for ARYG18LLTB.
Provides fan performance data for ARYG45LMLA (Static pressure mode 3).
Shows airflow rates for AUYG24LVLA (High ceiling mode).
Shows airflow rates for AUYG45LRLA (3-way air outlet).
Shows airflow rates for ARYG18LLTB.
Shows airflow rates for ARYG45LMLA.
Shows airflow rates for ABYG24LVTA.
Shows airflow rates for ABYG45LRTA.
Noise level curves for AUYG24LVLA.
Noise level curves for AUYG45LRLA.
Noise level curves for ARYG18LLTB.
Noise level curves for ARYG45LMLA.
Noise level curves for ABYG24LVTA.
Noise level curves for ABYG45LRTA.
Details safety devices for compact cassette indoor units.
Details safety devices for cassette indoor units.
Details safety devices for slim duct indoor units.
Details safety devices for duct indoor units.
Details safety devices for floor/ceiling indoor units.
Details safety devices for ceiling indoor units.
Identifies the outdoor units covered in this section.
Lists specifications for the AOYG72LRLA outdoor unit.
Lists specifications for the AOYG90LRLA outdoor unit.
Provides dimensional drawings for both AOYG72LRLA and AOYG90LRLA outdoor units.
Shows required clearances for single outdoor unit installations.
Details clearances for multiple outdoor units and piping space.
Provides wiring diagrams for the outdoor units.
Lists heating capacity tables for AOYG72LRLA.
Lists heating capacity tables for AOYG90LRLA.
Capacity compensation rates for AOYG72LRLA based on piping and height.
Capacity compensation rates for AOYG90LRLA based on piping and height.
General precautions for installing indoor units.
General precautions for installing outdoor units.
Key considerations for using R410A refrigerant and piping materials.
Details allowable height differences and piping lengths for optimal operation.
Guides on selecting correct pipe sizes for twin and triple configurations.
Details additional refrigerant charging for systems requiring it.
Formula and example for calculating additional refrigerant charge for triple systems.