SERVICE PARTS INFORMATION 5
Check Point : AR*18LUAD/ AR*24/ 30/ 36/ 45LUAN
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
90.3 8%
152 8%
222 8%
42.9 8%
42.9 8%
Resistance value
(AC)
Thermal protector
Pr
VIOLET
BLUE
PINK
RED
BLACK
WHITE
150°C
at 20°C
Indoor Unit Fan Motor
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
07-32
AR*18LUAD
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
19.7 8%
13.0 8%
5.86 8%
5.86 8%
5.86 8%
Resistance value
at 20°C
AR*30/ 36/ 45LUAN
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
50.9 8%
29.1 8%
8.96 8%
8.96 8%
8.96 8%
Resistance value
at 20°C
AR*24LUAN
Check Point : AR*45/ 54LUAK
Red Violet
Violet Blue
Red Black
White Red
Read Wire
6.84 8%
9.78 8%
6.10 8%
6.10 8%
Resistance value
(AC)
Thermal protector
Pr
VIOLET
BLUE
RED
BLACK
WHITE
150°C
at 20°C
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.