5. Thermistor resistance values
5-1. Indoor unit
¢ Room temperature thermistor
Temperature (°C) Resistance (kΩ) Voltage (V)
-10.0 58.25 0.73
-5.0 44.03 0.93
0.0 33.62 1.15
5.0 25.93 1.39
10.0 20.18 1.66
15.0 15.84 1.94
20.0 12.54 2.22
25.0 10.00 2.50
30.0 8.04 2.77
35.0 6.51 3.03
40.0 5.30 3.27
45.0 4.35 3.49
¢ Heat exchanger temperature thermistor
Temperature (°C) Resistance (kΩ) Voltage (V)
-30.0 1,131.91 0.21
-25.0 804.52 0.29
-20.0 579.59 0.40
-15.0 422.89 0.53
-10.0 312.27 0.69
-5.0 233.21 0.88
0.0 176.03 1.10
5.0 134.23 1.36
10.0 103.34 1.63
15.0 80.28 1.92
20.0 62.91 2.21
25.0 49.70 2.51
30.0 39.57 2.79
35.0 31.74 3.06
40.0 25.64 3.30
45.0 20.85 3.53
50.0 17.06 3.73
55.0 14.05 3.90
60.0 11.64 4.02
65.0 9.69 4.19