EasyManuals Logo

Fujitsu AS*12LMACW Service Instruction

Fujitsu AS*12LMACW
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
CONNECT
(Compressor wire)
BIND
(Fan motor wire)
1-2-2 WIRING (For AO*30LMAW4)
03-10
To Comp. top
Thermistor (Compressor temp.)
To discharge pipe
Thermistor (Discharge temp.)
Pass 4 wires through
behind this plate.
Thermistor (Outdoor temp.)
Thermistor
(Heat exchanger temp.)
Pressure SW wire
INSTALL
Thermistor (Discharge temp.)
+Holder (thermistor)
BINDER M
BINDER L
RUBBER(Discharge temp.)
Thermistor
(Discharge temp.)
Thermistor
(Compressor temp.)
Coil
(Expansion valve) wire
INS (PIPE)
CONNECT
Pressure SW wire
Thermistor (Outdoor temp.)
RIGHT VIEW
BACK VIEW
BIND (5 wires)
BINDER M
Thermistor (2-way valve temp.)x2
Thermistor (3-way valve temp.)x2
BIND (9 wires)
BINDER M
Thermistor (2-way valve temp.)x4
Thermistor (3-way valve temp.)x4
Thermistor (3-way valve temp.)
Thermistor (2-way valve temp.)
Thermistor (Heat exchanger temp.)