– 83 –
Refrigerant pipe
ø 6.35mm(1/4")
Refrigerant pipe
Suction pipe
ø 12.7mm(1/2")
Capillary
tube
Capillary
tube
Charging valve
Charging valve
2-Way valve
3-Way
valve
Compressor
Strainer
OUTDOOR UNITINDOOR UNIT
Condenser
Evaporator
Refrigerant pipe
ø 12.7mm(1/2")
Refrigerant pipe
Suction pipe
Coupling
pipe assy
ø 6.35mm(1/4")
2-Way
valve
4-Way
valve
3-Way
valve
Compressor
Dryer
Muffler
OUTDOOR UNITINDOOR UNIT
Condenser
Evaporator
Cooling
Heating
: Flare coupling
Models : AB 14A / AO 14A
Models : AB 14R / AO 14R