Model Name : AS*A09 / 12LKC
[Condition]
Ambient
temperature
IIndoor / Outdoor - Same temperature
Refrigerant
amount
Standard amount
Piping 5.0m (Height difference 1m)
Power
voltage
50Hz - 230V
Operation
condition
TEST mode (Heating), Hi Fan, Lower direction, Front air flow
Measuring
method
[Constant Frequency Operation Method (Test mode)]
1. Operate on Heating mode, and press TEST button of remote control.
2. Operate continuously for 30 minutes. (After 60 minutes of operation, Test mode is released automatically.)
(1) Indoor/Outdoor Temperature - Outdoor High Pressure Curve
AS*A09LKC
AS*A09LKC
AS*A12LKC
AS*A12LKC
(2) Indoor/Outdoor Temperature - Outdoor Total Electric Current Curve
Outdoor ambient temparature [degC] Outdoor ambient temparature [degC]
High-pressure of outdoor unit [MPa]
High-pressure of outdoor unit [MPa]
Outdoor ambient temparature [degC]
Outdoor ambient temparature [degC]
Outdoor total electric current [A]
length
03-03
Measure the high pressure with the pressure meter at the service valve.
Measure the outdoor unit overall current with the current clamp meter at Power Cable.
2-2 Heating operation
[50Hz-230V]
2.0
2.2
2.4
2.6
2.8
3.0
0 2 4 6 8 10 12 14
15 degC
20 degC (Indoor ambient temp.)
23 degC
[50Hz-230V]
2.6
2.8
3.0
3.2
3.4
3.6
3.8
0 2 4 6 8 10 12 14
[50Hz-230V]
5.6
6.0
6.4
6.8
7.2
7.6
0 2 4 6 8 10 12 14
15 degC
20 degC (Indoor ambient temp.)
23 degC
15 degC
20 degC (Indoor ambient temp.)
23 degC
Outdoor total electric current [A]
[50Hz-230V]
3.8
4.2
4.6
5.0
5.4
5.8
0 2 4 6 8 10 12 14
15 degC
20 degC (Indoor ambient temp.)
23 degC