EasyManuals Logo

Fujitsu AS G07LUCA Series User Manual

Fujitsu AS G07LUCA Series
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
1. Discharge pressure sensor connector disconnection, open eruliaf rosnes erusserp egrahcsiD .2
3. Main PCB failure
1
CN92
1
RED
PRESSURE SENSOR
WHITE
BLACK
PS
2 2
3 3
Trouble shooting 32
OUTDOOR UNIT Error Method:
Discharge Pressure Sensor Error
Discharge pressure sensor
=
Detective Actuators:
Detective details:
Indicate of Display:
Forecast of Cause:
02-47
When any of the following conditions is satisfied, a discharge pressure
sensor error is generated.
30 seconds or more have elapsed since the outdoor unit power was
turned on and pressure sensor detected value < 0.3V continued
for 30 seconds or more
30 seconds or more have elapsed since the outdoor unit power was
turned on and pressure sensor detected value > 5.0V was detected.
OK
Test 3 : Check voltage of Main PCB (DC5.0V)
DC
OK
Test 1 : Check the discharge pressure sensor connection state
Connector connection state check
Cable open check
Test 2 : Check the discharge pressure sensor
Sensor characteristics check
*For the characteristics of the discharge pressure sensor,
refer to the (SERVICE PARTS INFORMATION 4).
Main PCB (CN92:1-2) voltage value = 5V
Remove the PRESSURE SENSOR from Main PCB, check the voltage.
Discharge pressure sensor (CN92:1-2)
If the voltage does not appear, replace Main PCB,
and execute the check operation again.
Indoor Unit
Outdoor Unit
Operation lamp : 8 time Flash
ERROR CODE : [E : 86]
Timer lamp: 6 time Flash
Monitor
A B C D E F
8
: Light ON : Light OFF n : n time blinking
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AS G07LUCA Series and is the answer not in the manual?