3. INDOOR FAN CONTROL
01-03
1. Fan speed
( Table 2 : Indoor fan speed table)
Hi
Me+
Me
Lo
Quiet
Cool Air Prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
Operation mode
Heating
Cooling / Fan
Dry
Air flow mode
Fan Speed
ASU7RLF
1050
1000
950
850
720
600
480
1050
950
850
710
600
X, J zone:710
ASU9RLF
Hi
Me+
Me
Lo
Quiet
Cool Air Prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
Operation mode
Heating
Cooling / Fan
Dry
Air flow mode
Fan Speed
1100
1040
980
850
720
600
480
1100
980
850
710
600
X, J zone:710
ASU12RLF
Hi
Me+
Me
Lo
Quiet
Cool Air Prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
Operation mode
Heating
Cooling / Fan
Dry
Air flow mode
Fan Speed
1200
1130
1050
910
720
600
480
1200
1050
880
710
600
X, J zone:710
ASU18RLF
Hi
Me+
Me
Lo
Quiet
Cool Air Prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
Operation mode
Heating
Cooling / Fan
Dry
Air flow mode
Fan Speed
1260
1120
1020
900
790
680
480
1260
1020
900
770
680
X, J zone:770
ASU24RLF
Hi
Me+
Me
Lo
Quiet
Cool Air Prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
Operation mode
Heating
Cooling / Fan
Dry
Air flow mode
Fan Speed
1430
1320
1220
1020
900
720
480
1480
1220
1020
900
720
X, J zone:900
*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs.
(Hi > Me, Me > Lo, Quiet > Soft Quiet)
(rpm) (rpm)
(rpm)
(rpm)
(rpm)

Other manuals for Fujitsu AS* G09LECB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AS* G09LECB and is the answer not in the manual?

Fujitsu AS* G09LECB Specifications

General IconGeneral
BrandFujitsu
ModelAS* G09LECB
CategoryAir Conditioner
LanguageEnglish

Related product manuals