En-16
Dry Mode
About -10 to 43 °C
About 18 to 32 °C
Outdoor temperature
Indoor temperature
Cooling Mode
About -10 to 43 °C
About 18 to 32 °C
Heating Mode
About –15 to 24 °C
About 30 °C or less
Temperature and Humidity Range
If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to
prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than
those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip
onto the oor or other objects underneath. (About 80% or more).
If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the
outdoor unit may stop operation for certain period of time.
OPERATING TIPS
Operation and Performance
Heating Performance
This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuf cient
heating performance is being produced, we recommend you
use this air conditioner in conjunction with another kind of
heating appliance.
Heat-pump air conditioners heat your entire room by recircu-
lating air throughout the room, with the result that some time
may be required after rst starting the air conditioner until the
room is heated.
Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low outdoor
temperature and high humidity, frost may form on the outdoor
unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this unit is
equipped with a Microcomputer-controlled Automatic Defrost-
ing function. If frost forms, the air conditioner will temporarily
stop, and the defrosting circuit will operate brie y (for about
7-15 minutes).
During Automatic Defrosting operation, the OPERATION
Indicator Lamp (red) will ash.
AUTO Restart
In Event of Power Interruption
The air conditioner power has been interrupted by a power
failure. The air conditioner will then restart automatically in
its previous mode when the power is restored.
Operated by setting before the power failure.
If a power failure occurs during TIMER operation, the timer will
be reset and the unit will begin (or stop) operation at the new
time setting. In the event that this kind of timer fault occurs the
TIMER Indicator Lamp will ash (see Page. 3).
Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the air
conditioner to malfunction. In this event, temporarily discon-
nect the Power Supply Plug, reconnect it, and then use the
Remote Control Unit to resume operation.
9315161192-03.indb 169315161192-03.indb 16 2/26/2013 11:02:13 AM2/26/2013 11:02:13 AM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASBA18LEC: AOBR18LEC and is the answer not in the manual?

Fujitsu ASBA18LEC: AOBR18LEC Specifications

General IconGeneral
BrandFujitsu
ModelASBA18LEC: AOBR18LEC
CategoryAir Conditioner
LanguageEnglish

Related product manuals