EasyManua.ls Logo

Fujitsu ASBA24JFC - User Manual

Fujitsu ASBA24JFC
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EnglishEspañolPortuguês
P/N9315345332-03
OPERATING MANUAL
MANUAL DE FUNCIONAMIENTO
MANUAL DE INSTRUÇÕES
Indoor Unit
ASBA24JFC
Outdoor Unit
AOBR24JFC
COOL MODEL
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
GUARDE ESTE MANUAL DE USO PARA
FUTURAS CONSULTAS
GUARDE ESTE MMANUAL DE FUNCIONANENTO
PARA REFERÊNCIA FUTURA
FUJITSU GENERAL LIMITED
9315345332-03_Cover.indd 19315345332-03_Cover.indd 1 2/25/2013 10:12:17 AM2/25/2013 10:12:17 AM

Questions and Answers

Summary

Features and Functions

Name of Parts

Preparation

Operation

To Select Mode Operation

Guides the user on how to choose the operating mode (Auto, Cool, Dry, Fan).

To Set the Thermostat

Explains how to adjust the desired room temperature setting.

To Set the Fan Speed

Details how to select the fan speed for optimal airflow.

SUPER QUIET Operation

Describes the low-noise operation mode for reduced airflow.

Timer Operation

To Use the ON timer or OFF timer

Instructions for setting single ON or OFF timers for the air conditioner.

To Use the Program timer

Guide to setting integrated ON/OFF timer sequences within 24 hours.

Sleep Timer Operation

Manual Auto Operation

Adjusting the Direction of Air Circulation

Vertical Air Direction Adjustment

How to control the up/down airflow direction using the remote.

Horizontal Air Direction Adjustment

How to control the left/right airflow direction using the remote.

Swing Operation

Cleaning and Care

Cleaning the Intake Grille

Step-by-step guide to removing and cleaning the front intake grille.

Cleaning the Air Filter

Instructions for removing, cleaning, and replacing the air filters.

Air Cleaning Filter Installation

Guide to installing specialized air cleaning filters.

Replacing dirty Air cleaning filters

Instructions for replacing disposable air cleaning filters.

Maintenance of Deodorizing Filters

Procedure for cleaning and maintaining negative air ion filters.

Troubleshooting

Operating Tips

AUTO Restart

Details how the unit restarts automatically after a power interruption.

Temperature and Humidity Range

Specifies the optimal operating temperature and humidity limits.

Overview

This document is an operating manual for a Fujitsu INVERTER Cool Model Room Air Conditioner, specifically a wall-mounted type. It covers the indoor unit model ASBA24JFC and the outdoor unit model AOBR24JFC. The manual provides instructions in English, Spanish, and Portuguese.

Function Description

The Fujitsu INVERTER air conditioner is designed to provide efficient cooling for rooms. The inverter technology allows the unit to quickly reach the desired temperature at the start of operation, then automatically switch to a low power setting for economic and comfortable operation, maintaining a constant temperature.

The unit features an AUTO CHANGEOVER mode, which automatically switches between cooling and dry modes to maintain the set temperature.

For enhanced air circulation, it offers OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION), providing three-dimensional control over air direction swing (UP/DOWN and RIGHT/LEFT). The UP/DOWN air direction flaps operate automatically based on the selected operating mode.

A PROGRAM TIMER allows users to integrate OFF timer and ON timer operations in a single sequence within a twenty-four hour period. This can involve one transition from OFF timer to ON timer, or vice versa.

The SLEEP TIMER function, when activated during cooling, gradually raises the thermostat setting over the period of operation, and the unit automatically turns off once the set time is reached. This prevents excessive cooling during sleep.

For quieter operation, the SUPER QUIET OPERATION mode reduces the indoor unit's airflow.

The air conditioner is controlled by a WIRELESS REMOTE CONTROL UNIT, offering convenient operation. In case the remote control is lost or unavailable, MANUAL AUTO OPERATION can be initiated directly from the main unit's control panel.

Important Technical Specifications

  • Indoor Unit Model: ASBA24JFC
  • Outdoor Unit Model: AOBR24JFC
  • Operating Modes: Cool, Dry, Fan, Auto Changeover, Super Quiet.
  • Thermostat Setting Range:
    • AUTO: 18-30 °C
    • Cooling/Dry: 18-30 °C
  • Fan Speed Settings: Auto, High, Med, Low, Quiet.
  • Temperature and Humidity Range (Cooling Mode):
    • Outdoor temperature: About 18 to 46 °C
    • Indoor temperature: About 18 to 32 °C
  • Temperature and Humidity Range (Dry Mode):
    • Outdoor temperature: About 18 to 46 °C
    • Indoor temperature: About 18 to 32 °C
  • Remote Control Operating Range: About 7 meters.
  • Remote Control Batteries: Size AAA R03/LR03 × 2 (not included).

Usage Features

  • Starting/Stopping Operation: Press the START/STOP button on the remote control. The indoor unit's OPERATION Indicator Lamp (red) will light up when operating.
  • Mode Selection: Use the MODE button to cycle through AUTO, COOL, DRY, and FAN modes.
  • Temperature Adjustment: Use the SET TEMP. buttons (▲/▼) to raise or lower the thermostat setting.
  • Fan Speed Adjustment: Use the FAN button to cycle through AUTO, HIGH, MED, LOW, and QUIET fan speeds.
  • Air Direction Adjustment:
    • Vertical Air Direction: Use the SET button (Vertical) on the remote control to adjust the vertical airflow louvers. The range varies between cooling/dry modes and fan mode.
    • Horizontal Air Direction: Use the SET button (Horizontal) on the remote control to adjust the horizontal airflow louvers.
  • Swing Operation: Press the SWING button to enable up/down, left/right, or up/down/left/right swing operations.
  • Timer Functions:
    • ON/OFF Timer: Set specific times for the unit to turn on or off.
    • Program Timer: Combine ON and OFF timer operations in a sequence.
    • Sleep Timer: Automatically adjusts thermostat settings during sleep and turns off the unit after a set period.
  • AUTO Restart: In the event of a power interruption, the air conditioner will automatically restart in its previous mode once power is restored. If a power failure occurs during TIMER operation, the timer will be reset, and the unit will begin or stop operation at the new time setting.

Maintenance Features

  • Removable Open Panel: The indoor unit's Open Panel can be removed for easy cleaning and maintenance.
  • Air Filter Cleaning:
    1. Open the Intake Grille.
    2. Remove the air filter by lifting its handle and disconnecting the lower tabs.
    3. Clean dust with a vacuum cleaner or by washing with mild detergent and warm water. Allow to dry thoroughly in a shaded place.
    4. Replace the air filter and close the Intake Grille.
    • It is recommended to clean air filters every two weeks during normal use.
  • Mildew-Resistant Filter: The AIR FILTER has been treated to resist mildew growth, promoting cleaner use and easier care.
  • Polyphenol Catechin Air Cleaning Filter (UTR-FA13-1): These are disposable filters that use static electricity to clean fine particles, dust, tobacco smoke, and plant pollen. They contain catechin, which suppresses bacteria growth. These filters should be exchanged approximately every three months.
  • Negative Air Ions Deodorizing Filter (UTR-FA13-2): Composed of pottery super micro particles, these filters produce negative air ions for deodorizing and absorbing peculiar smells. They should be exchanged approximately every three years.
  • Deodorizing Filter Maintenance: To maintain deodorizing effect, clean the filter every three months by flushing with high-pressure hot water and diluent neutral detergent, rinsing, and drying in the shade. Do not rub or ream the filter.
  • Long-Term Shutdown: When shutting down the unit for one month or more, operate the fan mode continuously for about half a day to thoroughly dry internal parts.

Safety Precautions

The manual emphasizes several safety precautions, including:

  • Do not attempt self-installation or repairs; consult authorized service personnel.
  • Avoid prolonged exposure to direct cooling airflow.
  • Do not insert fingers or objects into outlet ports or intake grilles.
  • Do not start/stop operation by disconnecting the power cord.
  • In case of malfunction (e.g., burning smell), immediately stop operation, disconnect power, and consult service personnel.
  • Provide occasional ventilation during use.
  • Do not direct airflow at fireplaces or heating apparatus.
  • Do not climb on or place objects on the air conditioner.
  • Do not expose the unit to water or operate with wet hands.
  • Turn off the power source when not using the unit for extended periods.
  • Ensure air filters are installed and do not block intake grille or outlet port.
  • Keep electronic equipment at least one meter away from the units.
  • Avoid installing near fireplaces or heating apparatus.
  • Take precautions to prevent infant access to units.
  • Do not use inflammable gases near the air conditioner.

Fujitsu ASBA24JFC Specifications

General IconGeneral
BrandFujitsu
ModelASBA24JFC
CategoryAir Conditioner
LanguageEnglish

Related product manuals