OUTDOOR UNIT
AOTG09-22LV
OUTDOOR UNIT
AOTG09-22LV
MODEL
:AOTG12LV
Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.955 0.934
10 - - 0.998 0.955 0.934
7.5 - 1.000 0.998 0.955 0.934
5 0.991 1.000 0.998 0.955 0.934
0 0.991 1.000 0.998 0.955 0.934
2
Indoor unit is
under than
outdoor unit.
-5 0.986 0.995 0.993 0.951 0.930
-7.5 - 0.993 0.991 0.948 0.927
-10 - - 0.988 0.946 0.925
-15 - - - 0.936 0.916
COOLING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.894 0.895
10 - - 0.961 0.909 0.910
7.5 - 0.988 0.965 0.912 0.914
5 1.014 0.992 0.969 0.916 0.918
0 1.023 1.000 0.976 0.923 0.925
2
Indoor unit is
under than
outdoor unit.
-5 1.023 1.000 0.976 0.923 0.925
-7.5 - 1.000 0.976 0.923 0.925
-10 - - 0.976 0.923 0.925
-15 - - - 0.923 0.925