Trouble shooting 29
INDOOR UNIT
INDOOR UNIT Error Method:
Indicate or Display:
Refer to error code table.
Detective Actuators:
Detective details:
Forecast of Cause :
OKOK
VDD permanence stop protection
(Electric air clean)
Electric air clean unit
Indoor Unit Control PCB Circuit
When the air cleanness monitor trial protection operates 4 times.
1. Electric air clean unit failure 2. Control PCB failure
Check Point 1 : Check the Electric air clean unit
Check the Micro switch in Electric air clean unit.
(Check ON/OFF switching operation by using a meter.)
Check the front panel is closed.
02-35
Check Point 2 : Replace Controller PCB
If Check Point 1 do not improve the symptom, change Control PCB.
Check Point 2 : Replace Controller PCB
If Check Point 1 do not improve the symptom, change Control PCB.
Trouble shooting 30
INDOOR UNIT
INDOOR UNIT Error Method:
Indicate or Display:
Refer to error code table.
Detective Actuators:
Detective details:
Forecast of Cause :
OKOK
Reverse-VDD permanence stop protection
(Electric air clean power supply circuit
abnormal)
Electric air clean unit
Indoor Unit Control PCB Circuit
The air clean operation signal was detected for 1 minute at the time
of air clean mode OFF.
1. Electric air clean unit failure 2. Control PCB failure
Check Point 1 : Replace Electric air clean unit
Change Electric air clean unit.
>>If Micro switch is detective, replace Electric air clean unit.

Other manuals for Fujitsu ASU18RMLQ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASU18RMLQ and is the answer not in the manual?

Fujitsu ASU18RMLQ Specifications

General IconGeneral
BrandFujitsu
ModelASU18RMLQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals