Heating mode
F zone
E zone
D zone
C zone
B zone
A zone
66.2°F
(19°C)
32.0°F
(0°C)
5.0°F
(-15°C)
-13.0°F
(-25°C)
41.0°F
(5°C)
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOUG09LZAS1
AOUG12LZAS1
A zone 34
B zone 34
C zone 34
D zone 15
E zone 14
F zone 14
AOUG15LZAS1
A zone 30
B zone 30
C zone 30
D zone 13
E zone 10
F zone 10
1-5. Limitation of compressor rotation number by outdoor temperature - (04-6) - 1. Rotation number control of compressor