EasyManua.ls Logo

Fujitsu ASUG15LZAS

Fujitsu ASUG15LZAS
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH MED LOW QUIET
ASUG09LZAS
A zone 58 42 30 24
B zone 58 42 30 24
C zone 58 42 30 24
D zone 50 34 26 20
E zone 50 34 26 20
F zone 50 34 26 20
ASUG12LZAS
A zone 74 42 30 24
B zone 74 42 30 24
C zone 74 42 30 24
D zone 50 34 26 20
E zone 50 34 26 20
F zone 50 34 26 20
ASUG15LZAS
A zone 80 42 28 22
B zone 80 42 28 22
C zone 80 42 28 22
D zone 54 34 24 18
E zone 54 34 24 18
F zone 54 34 24 18
1-1. Cooling operation - (04-2) - 1. Compressor frequency control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu ASUG15LZAS

Related product manuals