Type
Wall mounted
Inverter heat pump
Model name ASUH09LMAS ASUH12LMAS
Operation range
Cooling
°F (°C) 64 to 90 (18 to 32)
%RH 80 or less
Heating °F (°C) 60 to 86 (16 to 30)
Remote controller type
Wireless (Wired, Mobile app*
5
[FGLair
™
] [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
– Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
– *
1
: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
– *
2
: Heating (5°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 5°FDB (-15.0°CDB)/4°FWB (-15.56°CWB).
– Test conditions are based on AHRI 210/240 2023.
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *
3
: Maximum current is maximum value when operated within the operation range.
• *
4
: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *
5
: Available on Google Play
™
store or on App Store
®
. Optional WLAN Adapter is also required. For details, refer to the setting manual.
M condition
Model name ASUH09LMAS
Capacity
Cooling
Rated
kW 2.64
Btu/h 9,000
Min.—Max.
kW 1.0—3.37
Btu/h 3,400—11,500
Heating
Rated
kW 3.52
Btu/h 12,000
Min.—Max.
kW 0.82—4.69
Btu/h 2,800—16,000
Heating
(17°F) *
Rated
kW 2.17
Btu/h 7,400
Max.
kW 3.09
Btu/h 10,550
Input power
Cooling
Rated
kW
0.585
Min.—Max. 0.14—1.27
Heating
Rated 0.79
Min.—Max. 0.14—1.67
Heating
(17°F) *
Rated 0.68
Max. 1.39
Current
Cooling
Rated A
3.0
Heating 3.9
EER Cooling
kW/kW 4.51
Btu/hW 15.4
COP Heating
kW/kW 4.46
Btu/hW 15.2
SEER Cooling Btu/hW 26.5
HSPF Heating Btu/hW 13.0
Power factor
Cooling
%
84.8
Heating 88.1
NOTES:
Specifications are based on the following conditions:
• Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
• Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
• *: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
• Test conditions are based on AHRI 210/240 2017.
• Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
1-1. Indoor unit
- (01-2) - 1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION