Installation space requirement
40 (1,000)
or more
40 (1,000)
or more
99 (2,500)
or more
11 (262)
or more
Strong and durable ceiling
Obstruction
Floor
Unit: in (mm)
Maximum height from floor to ceiling [Unit: in (mm)]
Standard 107 (2,700)
High ceiling 119 (3,000)
3-way direction setting:
4 (100) or more*
Unit: in (mm)
NOTES:
To set “3-direction”, optional Air Outlet Shutter Plate (UTR-YDZB) must be installed, and the
“outlet-direction” need to be switched to “3-way” by remote controller.
*When installing the indoor unit, be careful about the maintenance space.
In 3-way outlet mode, changing of ceiling height setting by function setting 20 is prohibited.
(Ceiling height setting [function setting 20] is allowed to be changed only in 4-way outlet mode.)
- 14 -