4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASUH30LPAS
AFR CFM 812
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
5 3 25.35 3.75 24.69 3.83 24.02 3.91 23.36 3.98 22.70 4.06
14 12 28.66 3.91 27.91 3.99 27.16 4.07 26.41 4.15 25.66 4.23
23 19 30.85 3.78 30.04 3.86 29.23 3.94 28.42 4.02 27.62 4.09
32 28 33.03 3.66 32.16 3.73 31.30 3.81 30.43 3.88 29.57 3.95
41 37 35.21 3.53 34.29 3.60 33.37 3.68 32.45 3.75 31.52 3.82
47 43 34.82 3.02 33.91 3.08 32.99 3.15 32.08 3.21 31.17 3.27
50 47 34.48 2.67 33.57 2.72 32.67 2.78 28.39 2.83 28.39 2.89
59 50 32.85 2.35 31.99 2.40 31.13 2.45 28.39 2.50 28.39 2.54
68 59 31.22 2.03 30.40 2.07 29.59 2.12 28.39 2.16 27.95 2.20
75 64 29.95 1.85 29.17 1.88 28.39 1.92 27.60 1.96 26.82 2.00
AFR
m
3
/h
1,380
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15.0 -16.1 7.43 3.75 7.23 3.83 7.04 3.91 6.85 3.98 6.65 4.06
-10.0 -11.1 8.40 3.91 8.18 3.99 7.96 4.07 7.74 4.15 7.52 4.23
-5.0 -7.2 9.04 3.78 8.80 3.86 8.57 3.94 8.33 4.02 8.09 4.09
0.0 -2.2 9.68 3.66 9.43 3.73 9.17 3.81 8.92 3.88 8.67 3.95
5.0 2.8 10.32 3.53 10.05 3.60 9.78 3.68 9.51 3.75 9.24 3.82
8.3 6.1 10.20 3.02 9.94 3.08 9.67 3.15 9.40 3.21 9.14 3.27
10.0 8.3 10.10 2.67 9.84 2.72 9.58 2.78 8.32 2.83 8.32 2.89
15.0 10.0 9.63 2.35 9.38 2.40 9.12 2.45 8.32 2.50 8.32 2.54
20.0 15.0 9.15 2.03 8.91 2.07 8.67 2.12 8.32 2.16 8.19 2.20
24.0 18.0 8.78 1.85 8.55 1.88 8.32 1.92 8.09 1.96 7.86 2.00
¢
Model: ASUH36LPAS
AFR CFM 812
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
5 3 26.90 3.96 26.19 4.03 25.49 4.12 24.78 4.20 24.08 4.28
14 12 30.41 4.12 29.62 4.20 28.82 4.29 28.02 4.38 27.23 4.46
23 19 32.73 3.99 31.87 4.07 31.01 4.15 30.16 4.23 29.30 4.31
32 28 35.04 3.85 34.13 3.93 33.21 4.01 32.29 4.09 31.37 4.17
41 37 37.36 3.72 36.38 3.79 35.40 3.87 34.43 3.95 33.45 4.02
47 43 36.94 3.19 35.97 3.25 35.01 3.32 34.04 3.38 33.07 3.45
50 47 36.58 2.81 35.62 2.87 34.67 2.93 30.12 2.99 30.12 3.04
59 50 34.85 2.48 33.94 2.53 33.03 2.58 30.12 2.63 30.12 2.68
68 59 33.12 2.14 32.26 2.19 31.39 2.23 30.12 2.28 29.66 2.32
75 64 31.78 1.95 30.95 1.99 30.12 2.03 29.29 2.07 28.45 2.11
AFR
m
3
/h
1,380
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15.0 -16.1 7.88 3.96 7.68 4.03 7.47 4.12 7.26 4.20 7.06 4.28
-10.0 -11.1 8.91 4.12 8.68 4.20 8.45 4.29 8.21 4.38 7.98 4.46
-5.0 -7.2 9.59 3.99 9.34 4.07 9.09 4.15 8.84 4.23 8.59 4.31
0.0 -2.2 10.27 3.85 10.00 3.93 9.73 4.01 9.46 4.09 9.20 4.17
5.0 2.8 10.95 3.72 10.66 3.79 10.38 3.87 10.09 3.95 9.80 4.02
8.3 6.1 10.83 3.19 10.54 3.25 10.26 3.32 9.98 3.38 9.69 3.45
10.0 8.3 10.72 2.81 10.44 2.87 10.16 2.93 8.83 2.99 8.83 3.04
15.0 10.0 10.21 2.48 9.95 2.53 9.68 2.58 8.83 2.63 8.83 2.68
20.0 15.0 9.71 2.14 9.45 2.19 9.20 2.23 8.83 2.28 8.69 2.32
24.0 18.0 9.31 1.95 9.07 1.99 8.83 2.03 8.58 2.07 8.34 2.11
- 9 -
4-2. Heating capacity
4. Capacity table
WALL MOUNTED
ASUH30-36LPAS
WALL MOUNTED
ASUH30-36LPAS