– 8 –
INDOOR PRINTED CIRCUIT BOARD
CIRCUIT DIAGRAM
POWER TRANSFORMER
POWER TRANS.
PRIMARY
THERMAL FUSE
POWER TRANS.
SECONDARY
POWER SUPPLY PCB
(PRL)
(PRL)
(RED)
(RED)
(GRY)
(GRY)
POWER
SWITCH
(ORG)
FAN CAPACITOR
(BLK) (RED)
(WHT)
(WHT)
(WHT)
(WHT)
(WHT)
(BLK)
(BLK)
(GRY)
(GRY)
MANUAL
AUTO SWITCH
(BRN)
(RED)
(ORG)
(PRL)
(GRN)
OPERATE
(RED)
TIMER (GRN)
SWING (ORG)
(YEL)
(BLU)
(BLU)
(PRL)
(GRY)
(WHT)
(BLK)
(WHT)
(WHT)
(WHT)
(BRN)
(BLU)
(BLK)
ASY12FSACW
ASY10FSACW
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
JP9
(YEL)
(WHT)
(BLU)
(BRN)
(BLU)
To Earth terminal
(GREEN / YELLOW)
(BRN)
(BLK)
(WHT)
(ORG)
THERMAL
FUSE (102°C)
FAN MOTOR
ROOM TEMPERATURE
THERMISTOR
PIPE TEMPERATURE
THERMISTOR
CHECKER
LOUVER
INDICATOR PCB
TERMINAL
BOARD
RELAY PCB
220/240V
50Hz
8
4
CONTROLLER PCB ASSEMBLY
ASY10FSACW : EZ-0980KWSE-C (GM-60089)
ASY12FSACW : EZ-0980LWSE-C (GM-60090)
SW101
VCC
D0
TEST
GND
CS
SK
D1
NC
MODEL CHANGING CODE
AUTO CHANGE OVER
HEATING TEMPERATURE CORRECTION 1
HEATING TEMPERATURE CORRECTION 2
AUTO RESTART
REMOTE CONTROL / CUSTOM CODE
MULTI / SINGLE
Models : ASY10FSACW
ASY12FSACW

Other manuals for Fujitsu ASY10FSACW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASY10FSACW and is the answer not in the manual?

Fujitsu ASY10FSACW Specifications

General IconGeneral
BrandFujitsu
ModelASY10FSACW
CategoryAir Conditioner
LanguageEnglish

Related product manuals