EasyManuals Logo

Fujitsu ASY17AS User Manual

Fujitsu ASY17AS
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
En-17
OPERATION DETAILS
COOLING/DRY MODE
*Heating Performance
This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.
Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.
Operation and Performance
*Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low out-
door air temperature high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.
In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate
briefly (for about 6 to 12 minutes).
During Automatic Defrosting operation, the OPERATION in-
dicator lamp (red) will flash.
*When Indoor and Outdoor Temperatures are High
When both indoor and outdoor temperatures are high dur-
ing use of the heating mode, the outdoor units fan may stop
at times.
*Low Ambient Cooling
When the outdoor temperature drops, the outdoor units fans
may switch to Low Speed.
Temperature and Humidity Range
Permissible ranges of temperature and humidity are as follows:
If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate,
interrupting the operation. If the unit is used under lower temperature conditions than those noted here, the heat exchanger
may freeze, causing water leakage or other malfunction.
Do not use the air conditioner for any purpose other than room cooling, room heating, room drying or fan.
Humidity
About 80 % or less
If the unit is used for long peri-
ods under high-humidity condi-
tions, condensation may form on
the surface of the indoor unit, and
drip onto the floor or other objects
underneath.
Outdoor
Temperature
About 18 to 46 °C
COOLING MODEL
HEAT & COOL
MODEL
(Reverse Cycle)
Temperature
About 18 to 32 °C
Indoor
HEAT & COOL
MODEL
(Reverse Cycle)
Outdoor
Temperature
About 0 to 21 °C
Indoor
Temperature
About 30 °C or less