2
HI-SPEED (dB) 37 - 37 COOL 37 - 37 HEAT 37 - 37
INDOOR UNIT
MED-SPEED (dB) 35 - 35 COOL 35 - 35 HEAT 34 - 34
LO-SPEED (dB) 33 - 33 COOL 33 - 33 HEAT 32 - 32
SUPER QUIET (dB) 31 - 31 COOL 30 - 30 HEAT 30 - 30
OUTDOOR UNIT (dB) 42 - 43 COOL 42 - 43 HEAT 44 - 45
NOISE LEVEL
Between 7.5 m and 10 m, when using a connection pipe other than that in the table, charge
additional refrigerant with 20 g /1 m as the criteria.
ADDITIONAL CHARGE OF REFRIGERANT
Refrigerant suitable for a piping length of 7.5 m is charged in the outdoor unit at the factory.
When the piping is longer than 7.5 m, additional charging is necessary.
For the additional amount, see the table below.
Pipe length 7.5 m 10 m
Additional refrigerant None 50 g
The maximum length of the piping is 10 m. If the units are further apart than this,
correct operation can not be guaranteed.