SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
CONTENTS
SPECIFICATIONS
. . . . . . . . . . . . . . . . . . . . . . .
1
DIMENSIONS
. . . . . . . . . . . . . . . . . . . . . . . . . .
2
REFRIGERANT SYSTEM DIAGRAM
. . . . .
3
CIRCUIT DIAGRAM
. . . . . . . . . . . . . . . . . . . .
4
ERROR CONTENTS
. . . . . . . . . . . . . . . . . . . .
5INDOOR PCB CIRCUIT DIAGRAM
. . . . . .
6OUTDOOR PCB CIRCUIT DIAGRAM
. . . .
8
DISASSEMBLY ILLUSTRATION
. . . . . . . . .
9
PARTS LIST
. . . . . . . . . . . . . . . . . . . . . . . . . . .
12
14STANDARD ACCESSORIES
. . . . . . . . . . . .
Models
Indoor unit Outdoor unit
ASYA12LCC AOYR12LCC

Other manuals for Fujitsu ASYA12LCC

Questions and Answers

  • J
    jpaulSep 2, 2025
    Why Fujitsu ASYA12LCC Air Conditioner shows serial reverse transfer error at starting up operation?
    • E
      Erik CollinsSep 2, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error at startup, it means the indoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • J
    Julie DominguezAug 31, 2025
    What does main relay error mean on Fujitsu ASYA12LCC?
    • O
      owensaraAug 31, 2025
      If your Fujitsu Air Conditioner displays a main relay error, it means that after 2 minutes 20 seconds of stopping operation, the signal from the outdoor unit is received even though the main relay is OFF. The main relay might be defective or the Controller PCB might be defective.
  • B
    Barbara SanchezAug 29, 2025
    What causes a room temperature thermistor defective in Fujitsu ASYA12LCC?
    • C
      candacehowardAug 30, 2025
      If your Fujitsu Air Conditioner shows a room temperature thermistor defect, it means the thermistor detected an abnormal temperature when the power was turned on. Check the thermistor resistance value. The controller PCB might be defective.
  • Q
    qedwardsAug 28, 2025
    What to do if my Fujitsu ASYA12LCC has indoor fan speed error?
    • C
      Clayton JohnsonAug 28, 2025
      If your Fujitsu Air Conditioner displays an indoor fan speed error, it means the indoor fan speed is 1/3 of the target frequency after 56 seconds from starting or changing the fan mode. Here’s what to check: * Check the fan motor connector for looseness or defective contact. * The fan motor might be defective. * The controller PCB might be defective.
  • G
    gclarkeAug 27, 2025
    What to do if my Fujitsu ASYA12LCC has indoor fan lock error?
    • K
      Kenneth BerryAug 27, 2025
      If your Fujitsu Air Conditioner displays an indoor fan lock error, it means the indoor fan speed is 0 rpm after 56 seconds from starting or changing the fan mode. Here’s what to check: * Check the fan motor connector for looseness or defective contact. * The fan motor might be defective. * The controller PCB might be defective.
  • L
    Linda BryantAug 25, 2025
    What causes IPM protection in my Fujitsu Air Conditioner?
    • D
      Denise GarciaAug 25, 2025
      If your Fujitsu Air Conditioner is showing IPM protection, it indicates that an abnormal current value has been detected. Here's what you should check: * Ensure that heat radiation is not blocked at the inlet or outlet. * Verify that the outdoor fan is functioning correctly and rotating. * The controller PCB might be defective.
  • L
    Luke AllenAug 22, 2025
    What to do if my Fujitsu ASYA12LCC shows excessive high pressure protection on cooling?
    • J
      joseph17Aug 23, 2025
      If your Fujitsu Air Conditioner is showing an excessive high pressure protection error during cooling, check the following: * Ensure that heat radiation is not blocked at the inlet or outlet. * Verify that the outdoor fan is functioning correctly and rotating. * Check for any issues with the refrigeration cycle.

Summary

Specifications

Compressor

Details about the compressor type, discrimination, and refrigerant.

Fan Motor

Details about fan motor power source and speed settings.

Dimensions

Refrigerant System Diagram

Circuit Diagram

Indoor PCB Circuit Diagram

Outdoor PCB Circuit Diagram

Error Contents

Disassembly Illustration

Parts List

Indoor Unit

Detailed list of indoor unit components and part numbers.

Outdoor Unit

Detailed list of outdoor unit components and part numbers.

Standard Accessories

Fujitsu ASYA12LCC Specifications

General IconGeneral
TypeSplit System
Cooling Capacity3.4 kW
Heating Capacity4.0 kW
Energy Efficiency Ratio (EER)3.21
Power Supply220-240 V, 50 Hz
Outdoor Unit Noise Level50 dB(A)
RefrigerantR410A
Outdoor Unit Dimensions (HxWxD)540x790x290 mm