REPLACEMENT PARTS
09-15
Model : AOYR24LCC
PROCESS
REGULATIONS
Like figure 1, assemble PWAB ASSY (CAPACITOR) to the SPACER
Pay attention to direction of the PWAB ASSY, when assembling PWB ASSY
(Have the wire with the terminal (white W12, purple W13) on the REACTOR side.)
Do the twist work with the following combination. (Twist it 1 time is to twist 360 .)
white W12 blue W7
purple W13 yellow W8
Like figure 2, wire lead wire. Insert TERMINAL in CONTACT certainly.
Be sure to fasten by WIRE CLAMPER after wiring.
Fit the wire in the groove firmly.
Fasten the wire with BINDER M.
three times
Assemble PWB ASSY(CAPACITOR) and Wiring
PWB ASSY (K05DG CAPACITOR)
BINDER M
Figure 1
PWB ASSY(CAPACITOR)
SPACER
BINDER M
REACTOR
Either will do, because
there is no polarity
WIRE CLAMPER
six times
60~70mm
1
2
1
2