SPECIFICATIONS
TYPE
(COOL&HEAT INVERTER) (COOL&HEAT INVERTER)
INDOOR UNIT
ASYB09LDC ASYB12LDC
OUTDOOR UNIT AOYS09LDC AOYS12LDC
COOLING CAPACITY( ) : Range
(kW) 2.6 (0.5~3.7) 3.5 (0.9~4.3)
HEATING CAPACITY( ) : Range (kW) 3.6 (0.5~6.1) 4.8 (0.9~6.7)
POWER SOURCE
(V) 230
FREQUENCY
(Hz)
50
RUNNING CURRENT (A)
COOLING 2.9
3.9 5.5
1.22 (0.25~2.30)0.81 (0.25~1.96)
4.3
HEATING
INPUT WATTS (kW)
COOLING 0.61 (0.25~1.38) 0.91 (0.25~1.61)
HEATING
EER (kW/kW)
COOLING 4.26 3.85
4.44 3.93
1.8
HEATING
MOISTURE REMOVAL 1.3
AIR CIRCULATION-Hi (m
3
/hr) C 595 H645 C 595 H645
ELECTRICAL DATA
COMPRESSOR
Note : Always use a vacuum pump to purge the air.
Refrigerant for purging the air is not charged in the outdoor unit at the factory.
DIMENSIONS
TYPE Hermetic type,4 pole, 3 phase , DC inverter motor, Rotary
DISCRIMINATION DA 89 X 1F-20F
REFRIGERANT R410A
(g)
(r.p.m.)
(r.p.m.)
950
1,050
POWER SOURCE (V) 230
HI-SPEED
MED-SPEED
INDOOR UNIT
LO-SPEED
QUIET
C 1,300 H 1,390
C 1,120 H 1,200
C 950 H 1,000
C 700 H 760
C 1,370 H 1,440
C 1,150 H 1,200
C 950 H 1,000
C 700 H 760
OUTDOOR UNIT C800 H760
INDOOR UNIT H x W x D (mm)
HxWxD (mm)
283 x 790 x 230
OUTDOOR UNIT 540 x 790 x 290
FAN MOTOR
(dB)
(dB)
HI-SPEED
MED-SPEED
INDOOR UNIT
LO-SPEED
QUIET
C39 H40
OUTDOOR UNIT
NOISE LEVEL
20 m
15m chargeless, 20g/m (>15m)
WEIGHTS
INDOOR UNIT
OUTDOOR UNIT
DA 89 X 1F-20F
( /hr)
C41 H41
C34 H35 C35 H35
C29 H28 C29 H28
C20 H21 C20 H21
C47 H48 C47 H49
Note : Noise was measured in accordance with JIS standards, Japan.
GROSS / NET (kg)
GROSS / NET (kg)
12 / 9.5
38 / 34 40 / 36
MAX PIPE LENGTH
ADDITIONAL REFRIGERANT
THICKNESSES OF ANNEALED COPPER PIPES
Nominal diameter
1/4
3/8
Outer diameter (mm)
6.35
9.52
R410A
0.80
0.80
[ref,] R22
0.80
0.80
Thickness (mm)
01-03