SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASYA07LCC
ASYA09LCC
ASYA12LCC
ASYA14LCC
ASYA18LCC
ASYB09LDC
ASYB12LDC
AOYR07LCC
AOYR09LCC
AOYR12LCC
AOYR14LCC
AOYR18LCC
AOYS09LDC
AOYS12LDC
INVERTER
SERVICE
INSTRUCTION
R410A

Other manuals for Fujitsu ASYB12LDC

Questions and Answers

  • S
    Spencer CameronSep 3, 2025
    What does serial reverse transfer error during the operation mean for Fujitsu Air Conditioner?
    • J
      Jonathan HawkinsSep 3, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error during operation, it means the indoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • J
    Jennifer EllisSep 18, 2025
    Why Fujitsu Air Conditioner has power supply frequency detection error?
    • K
      Kimberly WalkerSep 18, 2025
      If your Fujitsu Air Conditioner displays a power supply frequency detection error, it means the power supply frequency cannot be recognized after 4 seconds of power ON. The Controller PCB might be defective.
  • D
    Dana GarciaSep 16, 2025
    What does forced auto switch error mean on Fujitsu ASYB12LDC?
    • N
      Nancy HancockSep 16, 2025
      If your Fujitsu Air Conditioner displays a forced auto switch error, it means the forced auto switch has been ON for 30 consecutive seconds. Check if the forced auto switch is kept pressed. The forced auto switch might be defective or the Controller PCB might be defective.
  • S
    Sandra NicholsSep 14, 2025
    What to do if my Fujitsu Air Conditioner shows outdoor temperature thermistor error?
    • C
      Caitlin GonzalezSep 14, 2025
      If your Fujitsu Air Conditioner displays an outdoor temperature thermistor error, it means the detection value of the outdoor temperature thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • S
    Suzanne ButlerSep 12, 2025
    What does outdoor heat exchanger thermistor error mean for Fujitsu ASYB12LDC Air Conditioner?
    • A
      abookerSep 12, 2025
      If your Fujitsu Air Conditioner displays an outdoor heat exchanger thermistor error, it means the detection value of the outdoor heat exchanger thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • D
    Debbie BarberSep 12, 2025
    What to do if my Fujitsu Air Conditioner shows discharge thermistor error?
    • D
      David LopezSep 12, 2025
      If your Fujitsu Air Conditioner displays a discharge thermistor error, it means the detection value of the discharge thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • L
    Lucas ZimmermanSep 9, 2025
    What causes Indoor heat exchanger thermistor error in Fujitsu ASYB12LDC Air Conditioner?
    • J
      Joel GreenSep 9, 2025
      If your Fujitsu Air Conditioner shows an indoor heat exchanger thermistor error, it means the detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON. Check the thermistor resistance value. The controller PCB might be defective.
  • L
    Lauren StaffordSep 7, 2025
    What does serial forward transfer error during the operation mean for Fujitsu Air Conditioner?
    • X
      xrobinsonSep 7, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error during operation, it means the outdoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • J
    Jeffery DeckerSep 5, 2025
    Why Fujitsu ASYB12LDC Air Conditioner shows serial forward transfer error at starting up operation?
    • J
      jwilliamsSep 5, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error at startup, it means the outdoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • T
    Tracy HolmesAug 20, 2025
    Why my Fujitsu ASYB12LDC Air Conditioner does not operate at all?
    • T
      Thomas NunezAug 21, 2025
      If your Fujitsu Air Conditioner isn't operating, and the Operation Lamp and Timer Lamp aren't lit, you should check a few things: * Ensure the input power voltage from the exclusive circuit AC outlet is normal. * Make sure the AC plug is securely inserted into the AC outlet and isn't loose. * Verify that any connected cables are wired correctly. * Confirm that each connector is securely inserted.

Summary

SPECIFICATIONS

Model Specifications

Details on unit types, electrical specs, fan motor, dimensions, weight, noise, and pipe thickness.

DIMENSIONS

ASYA07;09 LCC & AOYR07;09 LCC Dimensions

Visual representations of indoor and outdoor unit dimensions for specific models.

ASYA12 LCC & AOYR12 LCC Dimensions

Visual representations of indoor and outdoor unit dimensions for specific models.

ASYB09;12 LDC & AOYS09;12 LDC Dimensions

Visual representations of indoor and outdoor unit dimensions for specific models.

ASYA14;18 LCC & AOYR14;18 LCC Dimensions

Visual representations of indoor and outdoor unit dimensions for specific models.

REFRIGERANT SYSTEM DIAGRAM

ASYA07;09 LCC & AOYR07;09 LCC Diagram

Shows the refrigerant flow for specific indoor/outdoor unit models.

ASYA12 LCC & ASYB;AOYS Models Diagram

Illustrates the refrigerant flow for specific indoor/outdoor unit models.

ASYA14;18 LCC Models Diagram

Depicts the refrigerant flow for specific indoor/outdoor unit models.

CIRCUIT DIAGRAM

ASYA07;09 LCC & AOYR07;09 LCC Circuit Diagram

Electrical schematic for indoor and outdoor units of specific models.

ASYA12 LCC & AOYR12 LCC Circuit Diagram

Electrical schematic for indoor and outdoor units of specific models.

ASYB09;12 LDC & AOYS09;12 LDC Circuit Diagram

Electrical schematic for indoor and outdoor units of specific models.

ASYA14;18 LCC & AOYR14;18 LCC Circuit Diagram

Electrical schematic for indoor and outdoor units of specific models.

DESCRIPTION OF EACH CONTROL OPERATION

Cooling Operation

Explains the cooling capacity control based on temperature and frequency.

Heating Operation

Details heating capacity control related to temperature and compressor frequency.

Dry Operation

Describes indoor unit control for dry operation, including compressor frequency.

Auto Changeover Operation

Explains automatic switching between operation modes based on temperature.

Indoor Fan Control

Covers fan speed settings and fan operation modes for various models.

Outdoor Fan Control

Details outdoor fan motor types and fan speed control methods.

Louver Control

Explains vertical louver and swing operations for airflow direction.

Compressor Control

Covers compressor operation frequency ranges and start-up control.

Timer Operation Control

Describes available timer settings (ON/OFF, Program, Sleep) and their functions.

Electronic Expansion Valve Control

Explains how the electronic expansion valve is controlled based on various sensor inputs.

Test Operation Control

Details how to activate and perform test operation for troubleshooting.

Prevent to Restart for 3 Minutes

Describes the delay mechanism preventing compressor restart immediately after stopping.

Four-Way Valve Extension Select

Explains the switching logic of the four-way valve between modes.

Auto Restart

Covers how operation contents are memorized and restored after power interruption.

Manual Auto Operation

Explains the manual auto operation function for situations without remote control.

Forced Cooling Operation

Details the procedure for forced cooling operation, its duration, and indicators.

Compressor Preheating

Explains the preheating process for the compressor based on outdoor temperature.

Coil Dry or Air Clean Operation Control

Describes the coil-dry and air-clean functions and their operating parameters.

Defrost Operation Control

Details the conditions for starting and completing defrost operations based on temperature and time.

Off Defrost Operation Control

Explains the automatic defrost operation when heating mode stops and frost is present.

Various Protections

Covers protections like discharge gas temperature, current release, antifreezing, and pressure overrise.

REFRIGERANT CAUTION -R410 A-

R410 A Tools and Equipment

Lists and describes specialized tools required for R410A refrigerant handling.

Precaution for Installation

Provides crucial installation precautions related to R410A piping and materials.

Precaution for Servicing

Outlines precautions for servicing, focusing on refrigerant oil and pressure differences.

New Refrigerant R410 A Information

Information on HFC refrigerants, Montreal protocol, and refrigerant characteristics.

Difference from Conventional Model (R22) and Precautions

Compares R410A with R22 models, detailing differences in oil, compressor, and heat exchangers.

TROUBLE SHOOTING

Unit Does Not Operate

Troubleshooting steps for when the unit fails to operate or lights are off.

Self Diagnosis Function

Explains how to use the self-diagnosis function and interpret error indications.

Troubleshooting Methods

General methods for diagnosing issues including serial signals, IPM protection, and refrigerant cycles.

Serial Signal Receiving Error

Diagnosing errors related to communication between indoor and outdoor units.

IPM Protection

Troubleshooting steps for IPM protection faults, typically in the outdoor unit.

Refrigerant Cycle Troubleshooting

Identifies common refrigerant cycle issues and methods for diagnosing them.

APPENDING DATA

Jumper Setting

Details jumper settings for indoor and outdoor units, including custom codes and auto-restart.

Outdoor Unit Pressure and Current Curves

Provides graphs showing pressure and current values under various temperature conditions.

Thermistor Resistance Values

Tables and charts showing thermistor resistance at different temperatures.

Capacity;Input Data

Graphs illustrating heating and cooling capacity and input data at different operating conditions.

REPLACEMENT PARTS

Indoor Unit Replacement Parts

Exploded views of indoor unit components for various models.

Outdoor Unit Replacement Parts

Exploded views of outdoor unit components for various models.

Wiring and Assembly Procedures

Instructions for wiring, connecting, shaping, and fixing leads for various components.

INSTALLATION MANUAL

Mounting Position Selection

Guidance on choosing optimal locations for indoor and outdoor units.

Indoor Unit Installation

Instructions for installing the indoor unit, including mounting and piping.

Outdoor Unit Installation

Guidelines for installing the outdoor unit, including placement and safety.

Piping and Air Purge Procedures

Steps for connecting pipes, flaring, and purging air from the refrigerant system.

Finishing and Test Running

Steps for insulating, sealing, and performing initial test operations.

Fujitsu ASYB12LDC Specifications

General IconGeneral
TypeSplit System
Heating Capacity4.0 kW
RefrigerantR410A
Indoor Unit Weight9 kg
Noise Level (Indoor)21 dB(A)