(2/2)
Cooling
*Both capacity and input decrease when temperature is 19 or less degrees C, for compressor
frequency restrictions operate.
*Both capacity and input decrease when temperature is 40 or more degrees C, as compressor speed is
decreased due to current release protection.
*Both capacity and input change largely when temperature is 10 or less degrees C, as outdoor fan speed
is decreased due to low ambient temperature cooling control.
*Both capacity and input change more largely at less than 0 degrees C of ambient temperature as
outdoor fan speed is decreased further.
<Capacity>
< Input >
60%
70%
80%
90%
100%
110%
120%
130%
140%
150%
-10 0 10 20 30 40
Capacity(%)
19
43
20%
30%
40%
50%
60%
70%
80%
90%
100%
110%
120%
-10 0 10 20 30 40
Input(%)
19
43
Indoor : 27/19 C
Outdoor DB( C)
Indoor : 27/19 C
Outdoor DB( C)
08-14