1. Specifications
Type
Wall mounted
Inverter heat pump
Model name ASYG30KMTA ASYG36KMTA
Power supply 230 V ~ 50 Hz
Power supply intake Outdoor unit
Available voltage range 198—264 V
Capacity
Cooling
Rated
kW 8.0 9.4
Btu/h 27,300 32,100
Min.—Max.
kW 2.9—9.0 2.9—10.0
Btu/h 9,900—30,700 9,900—34,100
Heating
Rated
kW 8.8 10.1
Btu/h 30,000 34,500
Min.—Max.
kW 2.2—11.0 2.7—11.2
Btu/h 7,500—37,500 9,200—38,200
Input power
Cooling
Rated
kW
2.33 3.16
Min.—Max. 0.54—3.86 0.54—4.30
Heating
Rated 2.20 2.73
Min.—Max. 0.48—4.23 0.48—4.30
Fan
HIGH
W
62.0
MED 36.5
LOW 21.0
QUIET 11.5
Current
Cooling
Rated A
10.2 13.9
Heating 9.7 12.0
EER Cooling
kW/kW
3.43 2.97
COP Heating 4.00 3.70
Sensible capacity Cooling kW 6.15 6.70
Power factor
Cooling
%
99
Heating 99
Moisture removal L/h (pints/h) 2.6 (4.6) 3.8 (6.7)
Maximum operating current*
1
Cooling
A
21.0 21.5
Heating 21.0 21.5
Fan
Airflow rate
Cooling
HIGH
m
3
/h
1,330
MED 1,100
LOW 920
QUIET 720
Heating
HIGH 1,330
MED 1,100
LOW 920
QUIET 720
Type × Q'ty Sirocco fan × 1
Motor output W 61
Sound pressure level*
2
Cooling
HIGH
dB (A)
50
MED 44
LOW 40
QUIET 33
Heating
HIGH 49
MED 44
LOW 39
QUIET 33
Heat exchanger
Dimensions (H × W × D)
mm
Main: 448 × 900 × 30
Sub1: 84 × 900 × 13.3
Sub2: 126 × 900 × 13.3
Fin pitch Main: 1.2, Sub: 1.4
Rows × Stages Main: 3 × 28, Sub1: 1 × 4, Sub2: 1 × 6
Pipe type Copper tube
Fin type Aluminum
Enclosure
Material Polystyrene
Color
White
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
340 × 1,150 × 280
Gross 405 × 1,270 × 450
Weight
Net
kg
18.5
Gross 24.5
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas Ø 15.88 (Ø 5/8)
Method Flare
Drain hose
Material PVC
Size mm Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote controller
Wireless or Mobile app (FGLair*
3
) (Wired [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5.0 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play store or on App Store. For details, refer to the setting manual.
• This data is based on EN 14511 standard.
- 2 -
1. Specifications
WALL MOUNTED
ASYG30-36KMTA
WALL MOUNTED
ASYG30-36KMTA