2. FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH,
while the indoor fan only runs.
When Fan mode is set at (Auto), it operates on [MED] Fan Speed.
01-06
Operation mode Air flow mode
Speed (rpm)
650
620
580
520
460
400
300
650
580
520
460
400
460
300
Dry
Monitoring
Cooling
Fan
Heating
AU*G12LVLB
*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs.
(Hi > Me, Me > Lo, Lo > Quiet, Quiet > Soft Quiet)
Hi
Me+
Me
Lo
Quiet
Cool air prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
S-Lo
Operation mode Air flow mode
Speed (rpm)
830
770
730
630
500
400
300
730
630
540
460
400
460
300
Dry
Monitoring
Cooling
Fan
Heating
AU*G18LVLB
Hi
Me+
Me
Lo
Quiet
Cool air prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
S-Lo
Operation mode Air flow mode
Speed (rpm)
830
770
730
630
500
400
300
730
630
540
460
400
460
300
Dry
Monitoring
Cooling
Fan
Heating
AU*G14LVLB
Hi
Me+
Me
Lo
Quiet
Cool air prevention
S-Lo
Hi
Me
Lo
Quiet
*Soft Quiet
Auto
S-Lo