AIR CONDITIONER
Multi: 2, 3, 4 rooms type
DESIGN & TECHNICAL MANUAL
INDOOR
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF ARU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU7RLF*
ASU9RLF*
ASU12RLF*
ASU9RLS2*
ASU12RLS2*
ASU15RLS2*
ASU18RLF
ASU24RLF
AGU9RLF
AGU12RLF
AGU15RLF
*: AOU36RLXFZ1 is not connectable.
OUTDOOR
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ1
DR_MU008EF_07
2018.06.14

Table of Contents

Other manuals for Fujitsu AUU9RLF

Questions and Answers

  • D
    David DeleonAug 12, 2025
    What to do if my Fujitsu Air Conditioner remote is not working due to a communication error?
    • D
      David ChapmanAug 12, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • R
    Reginald DodsonAug 15, 2025
    What to do if my Fujitsu AUU9RLF Air Conditioner has a drainage error?
    • C
      Christian JohnstonAug 15, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • T
    tyler93Aug 23, 2025
    What to do if my Fujitsu AUU9RLF Air Conditioner shows an indoor room thermistor error?
    • D
      David WolfeAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • H
    hogandavidAug 27, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu AUU9RLF?
    • M
      Mary GallagherAug 27, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • J
    James DavisAug 30, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu AUU9RLF?
    • G
      George WardAug 31, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • V
    Valerie PierceSep 3, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu AUU9RLF?
    • C
      Courtney RobinsonSep 4, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • C
    carloscrawfordSep 7, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu AUU9RLF?
    • M
      Margaret SuttonSep 7, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.
  • K
    Keith DavisSep 10, 2025
    How to fix a Fujitsu AUU9RLF Air Conditioner indoor unit fan motor error?
    • A
      Ashley JohnsonSep 12, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.

Summary

Part 1. INDOOR UNIT

1. Model lineup

Lists all available indoor unit models and their types.

2. Indoor Unit Specifications

Detailed technical specifications for various indoor unit types (cassette, slim duct, etc.).

3. Indoor Unit Dimensions

Provides physical dimensions and installation space requirements for indoor units.

8. Indoor Unit Noise Level Curve

Presents noise level data for indoor units across different frequency bands.

13. Remote Controller

Details types, functions, and specifications of wireless and wired remote controllers.

14. Indoor Unit Function Settings

Explains how to adjust indoor unit functions via jumper wires or remote controllers.

15. Indoor Unit Accessories

Lists included accessories for different indoor unit types.

17. Indoor Unit Installation Precautions

General precautions and points to remember when installing indoor units.

Part 2. OUTDOOR UNIT (2 ROOMS TYPE)

1. Outdoor Unit Specifications (AOU18 RLXFZ)

Technical specifications for the AOU18RLXFZ outdoor unit.

2. Outdoor Unit Dimensions (AOU18 RLXFZ)

Physical dimensions of the AOU18RLXFZ outdoor unit.

3. Outdoor Unit Installation Space (AOU18 RLXFZ)

Provides installation space requirements for single and multiple outdoor units.

5. Outdoor Unit Wiring Diagram (AOU18 RLXFZ)

Electrical wiring diagram for the AOU18RLXFZ outdoor unit.

6. Outdoor Unit Capacity Table (AOU18 RLXFZ)

Lists cooling and heating capacities for various indoor unit combinations.

10. Outdoor Unit Operation Noise (AOU18 RLXFZ)

Noise level curves for cooling and heating operations.

11. Outdoor Unit Electrical Characteristics (AOU18 RLXFZ)

Electrical specifications including power supply, MCA, and wiring.

14. Outdoor Unit Installation Precautions (AOU18 RLXFZ)

General precautions for installing outdoor units.

Part 3. OUTDOOR UNIT (3 ROOMS TYPE)

1. Specifications

Technical specifications for the AOU24RLXFZ outdoor unit.

2. Dimensions

Physical dimensions of the AOU24RLXFZ outdoor unit.

3. Installation space

Provides installation space requirements for single and multiple outdoor units.

5. Wiring diagram

Electrical wiring diagram for the AOU24RLXFZ outdoor unit.

6. Capacity table

Lists cooling and heating capacities for various indoor unit combinations.

10. Operation noise (sound pressure)

Noise level curves for cooling and heating operations.

11. Electrical characteristics

Electrical specifications including power supply, MCA, and wiring.

14. Outdoor unit installation precautions

General precautions for installing outdoor units.

Part 4. OUTDOOR UNIT (4 ROOMS TYPE)

1. Specifications

Technical specifications for the AOU36RLXFZ1 outdoor unit.

2. Dimensions

Physical dimensions of the AOU36RLXFZ1 outdoor unit.

3. Installation space

Provides installation space requirements for single and multiple outdoor units.

5. Wiring diagram

Electrical wiring diagram for the AOU36RLXFZ1 outdoor unit.

6. Capacity table

Lists cooling and heating capacities for various indoor unit combinations.

10. Operation noise (sound pressure)

Noise level curves for cooling and heating operations.

11. Electrical characteristics

Electrical specifications including power supply, MCA, and wiring.

14. Outdoor unit installation precautions

General precautions for installing outdoor units.

Fujitsu AUU9RLF Specifications