Fujitsu AUXG18KVLA Service Manual

Fujitsu AUXG18KVLA
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
Error contents
POWER/
MODE
ERROR
PUMP
DOWN
LOW NOISE PEAK CUT
L1 L2 L3 L4 L5 L6
E: 84. Current sensor error (Outdoor
unit)
2
8
4
E: 86. High pressure switch error
(Outdoor unit)
2
8
6
E: 86. Pressure sensor error (Outdoor
unit)
2
8
6
E: 94. Trip detection (Outdoor unit)
2
9
4
E: 95. Compressor motor control error
(Outdoor unit)
2
9
5
E: 97. Outdoor unit fan motor error
(Outdoor unit)
2
9
7
E: 99. 4-way valve error (Outdoor unit)
2
9
9
E: A1. Discharge temperature error
(Outdoor unit)
2
10
1
E: A3. Compressor temperature error
(Outdoor unit)
2
10
3
E: A5. Low pressure error (Outdoor
unit)
2
10
5
E: AC. Heat sink temperature error
(Outdoor unit)
2
10
12
: Light on
: Light off
(n) : n Times blinking
1-4. Error code table (Outdoor unit: for 36/45/54 model only) - (03-4) - 1. Error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu AUXG18KVLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AUXG18KVLA and is the answer not in the manual?

Fujitsu AUXG18KVLA Specifications

General IconGeneral
BrandFujitsu
ModelAUXG18KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals