EasyManua.ls Logo

Fujitsu GENERAL AOHG24KBTB - 11. Safety devices

Fujitsu GENERAL AOHG24KBTB
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Safety devices
Type of
protection
Protection form
Model
AOHG18KBTB AOHG22KBTB
Circuit
protection
Current fuse (Main PCB)
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
Fan motor
protection
Terminal protection program
Activate
125±10 °C
Fan motor stop
Reset
120±10 °C
Fan motor restart
Compressor
protection
Terminal protection program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Terminal protection program
(Compressor temp.)
Activate
108 °C
Compressor stop
Reset
After 3 minutes, and 80 °C
or less
Compressor restart
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY
mode)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart
High pressure
protection
Pressure switch
Activate
4.2
+0
-0.15
MPa
Compressor stop
Reset
3.2 ±0.15 MPa
Compressor restart
Type of
protection
Protection form
Model
AOHG24KBTB AOHG30KBTB
Circuit
protection
Current fuse
(Main PCB)
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
250 V, 30 A
250 V, 3.15 A
250 V, 10 A × 2
Fan motor
protection
Thermal protection program
Activate
125 ±10 °C
Fan motor stop
122 ±9 °C
Fan motor stop
Reset
120 ±10 °C
Fan motor restart
107—126 °C
Fan motor restart
Compressor
protection
Thermal protection program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Compressor temp.)
Activate
108 °C
Compressor stop
Reset
80 °C or less
Compressor restart
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY
mode)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart
- 96 -
11. Safety devices
OUTDOOR UNIT
AOHG18-45KBTB
OUTDOOR UNIT
AOHG18-45KBTB

Table of Contents

Related product manuals