EasyManua.ls Logo

Fujitsu GENERAL AOHG24KBTB - 6-2. Model: AOHG22 KBTB

Fujitsu GENERAL AOHG24KBTB
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-2. Model: AOHG22KBTB
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5 7.5 10 15 20 25 30
Height difference H (m)
Indoor unit is higher
than outdoor unit *
1
25 0.909 0.909 0.903
15 0.953 0.950 0.947 0.941
10 0.983 0.968 0.966 0.962 0.956
7.5 0.988 0.987 0.972 0.970 0.966 0.960
5 0.992 0.992 0.991 0.976 0.974 0.970 0.964
0 1.000 1.000 0.999 0.984 0.982 0.978 0.972
Indoor unit is lower than
outdoor unit *
2
-5 1.000 1.000 0.999 0.984 0.982 0.978 0.972
-7.5 1.000 0.999 0.984 0.982 0.978 0.972
-10 0.999 0.984 0.982 0.978 0.972
-15 0.984 0.982 0.978 0.972
-25 0.982 0.978 0.972
HEATING
Pipe length (m)
5 7.5 10 15 20 25 30
Height difference H (m)
Indoor unit is higher
than outdoor unit *
1
25 0.894 0.867 0.839
15 0.920 0.894 0.867 0.839
10 0.982 0.920 0.894 0.867 0.839
7.5 1.000 0.982 0.920 0.894 0.867 0.839
5 1.000 1.000 0.982 0.920 0.894 0.867 0.839
0 1.000 1.000 0.982 0.920 0.894 0.867 0.839
Indoor unit is lower than
outdoor unit *
2
-5 0.995 0.995 0.977 0.916 0.889 0.862 0.836
-7.5 0.993 0.975 0.913 0.887 0.860 0.832
-10 0.972 0.911 0.885 0.858 0.830
-15 0.902 0.876 0.849 0.821
-25 0.851 0.821 0.795
- 83 -
6-2. Model: AOHG22KBTB
6. Capacity compensation rate for pipe length and height difference
OUTDOOR UNIT
AOHG18-45KBTB
OUTDOOR UNIT
AOHG18-45KBTB

Table of Contents

Related product manuals