FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide
July 2019, Ver.2.0
PCI Box
MC-0HPB32
- 1 x PCI Box has 2 x connection ports to connect to PCI Box Connection Cards.
1 x connection port is used to support 6 x PCI Cards.
If 2 x connection ports are used to connect 2 x PCI Box Connection Cards,
max. 12 x PCI Cards can be mounted.
- 1 x PCI Box can be connected to two different I/O units or one I/O unit with 2x connection ports.
- No PSU is included. Min. 1 x PSU for PCI Box needs to be mounted.
- Fans are mounted with redundant configuration as default configuration.
- Rack space : 4U
- PCI cards are hot plugable.
- 12 x PCI Card Cassettes are included.
- PCI Cards with Full Height bracket need to be chosen.
PSU for PCI Box
MC-0HPS51 / MCX0HPS51 (LD)
- 1 x PSU is included.
- Max. 2 x PSUs can be mounted per PCI Box for redundancy.
PCI Box Connection Card
MC-0JPC21 / MCX0JPC21 (LD)
- PCI Slots with Low Profile bracket are supported.
- 6 x PCI Cards in a PCI Box can be supported per connection port.
- 1 x PCI Box Connection Cable (2m long) is included.
- Max. 8 x PCI Box Connection Cards can be mounted per Base Unit.
next page
Base Units and PCI Boxes need to have the same power supply condition.
Required quantity
PSU Power cord
Not available
1
1 1
AC 200V Available (*1)
11
2 2
Dual Available (*2) 1×2 2 2
(*1) Single power feed configuration will help to supply power even in the event of PSU failure.
(*2) Dual power feed configuration will help to supply power even in the event of one Power feed failure or PSU failure.
# of PSU
Single
11.PCI Box
Input voltage
Power feed
Redundancy
Base Unit
SB
I/O Unit
PCI slot
LAN port
PCI_Box_Conn
PCI_Box_Conn
PCI Box
PCI slot PCI slot
To connect a PCI Box, a PCI Box Connection Card needs to be ordered and mounted in an I/O Unit.
1 x PCI Box cannot be connected to 2 different Base Units of PRIMEQUEST.