FUJITSU Server PRIMEQUEST 3800E2 System Configuration Guide
13.Rack Installation for APAC and Americas July 2019, Ver.2.0
For the details of rack products, please refer to "19 inch Rack Handbook".
https://globalpartners.ts.fujitsu.com/sites/primeweb/services/servers/primequest/document/Pages/dc-h-guide.aspx
24U (Width 700mm x Depth 1,050mm x Height 1,200mm)
37U (Width 700mm x Depth 1,050mm x Height 1,792mm)
42U (Width 700mm x Depth 1,050mm x Height 2,000mm)
16U (Width 600mm x Depth 1,050mm x Height 845mm)
24U (Width 600mm x Depth 1,050mm x Height 1,200mm)
42U (Width 600mm x Depth 1,050mm x Height 2,000mm)
Tilt-Resistant Stabilizer
For Model 2724/2737/2742/2616/2624/2642
For Base Rack for Model 2724/2737/2742
For front side, rear side, left side, and right side
For Expansion Rack for Model 2724/2737/2742
For front side and rear side
For Base Rack for Model 2616/2624/2642
For front side, rear side, left side, and right side
For Expansion Rack for Model 2616/2624/2642
For front side and rear side
Cable Holder for front side
* For Model 2724/2737/2742
Cable Holder for rear side
* For Model 2724/2737/2742
Cable Holder for front side
Cable Holder for rear side
Cable Holder for front side
Cable Holder for rear side
50 pcs of M6 screws and 50 pcs of M6 cage nuts
- can be used to mount PRIMEQUEST to Rack Units which
are delivered from Fujitsu factories (Japan and Germany).
- is bundled with PRIMEQUEST Base Unit.
Tilt-Resistant Stabilizer:
- If racks are not fixed to the floor, stabilizers should be
ordered and jointed to the racks.
- is NOT bundled with rack. Needs to be purchased.
- is used to prevent outflow of heated air into a vacant space.
- space to joint Side Cable Duct, if they are not jointed,
should be covered with Blank Panels.
For Model 2724: 2 spaces (1U)
For Model 2737/2742: 4 spaces (1U)
- is NOT bundled with racks. Needs to be purchased.
- Needs to be purchased if equipments do not include
screws or nuts to be fixed in a rack.
- is NOT bundled with the 19 inch racks.
- NOT include Stabilizer, Blank Panel or screw kits.
Please purchase them together with the Rack Unit,
if necessary.
- is used to draw cables connected from the front side of
equipments to the rear side of rack without occupying rack
space by jointing the Side Cable Ducts to the apertures in
the sides of racks.
Model2724 : one aperture on each of left and right sides
Mdel2737/2742: 2 apertures on each of left and right sides
- can accommodate around 90 cables with 5mm diameter.
- If one aperture is not jointed with Side Cable Duct, the
aperture should be covered with one 1U Blank Panel
(19R-26BP1), which needs to be purchased.
* Cable holders bundled to each rack:
Model 2724: 6 pcs per Rack
Model 2737: 8 pcs per Rack
Model 2742: 10 pcs per Rack
Model 2616: 4 pcs per Rack
Model 2624: 6 pcs per Rack
Model 2642: 10 pcs per Rack
If the bundled quantity is insufficient, please purchase additional
- can fix racks to floor by anchoring racks to floor and
using the kit holes.
- To fix Earthquake-Proof Kit, please consult constructors.