42 Service Supplement TX100 S1
Replacing the system board Replacement routines
Figure 26: Position of the screws
Ê Remove the five screws from the system board.
Ê Lift the system board slightly using the PCI socket, thereby you lift the
system board out of the centre rings of the spacer bolts.
V CAUTION!
Never take hold of the heat sinks!
Ê Carefully lift the system board out of the housing in a slight angle. Thereby
you pull the connectors out of the connector panel.
Ê Check the settings on the new system board (for a description see the
Technical Manual of the system board).
Ê Insert the system board by holding it at a slight angle. Slide the connectors
into the connector panel.
V CAUTION!
Don’t damage the EMI springs to comply with applicable EMC regula-
tions and satisfy cooling requirements and fire protection measures.