En-11
(3) Touch [ ] button to display the Refrigerant system
address and Indoor unit address.
(a)
(b)
(c)
(d)
(1) (2) (3)
(a) System number (002: Indoor unit)
(b) Unit number (01 to 32)
(c) Refrigerant system address (00 to 99)
(d) Indoor unit address (00 to 63)
(4) Touch [
] button to return to previous screen.
8.2.5. Check the indoor unit position [No.11]
Note
This item cannot be set from slave remote controllers.
(1) Select the “11” in F2 settings. Then touch [
] button.
(2) Display 2-wire remote controller address of indoor unit
that noti es position.
(1)
(2)
2-wire remote
controller address
(3) When touch [
] button, the appropriate indoor unit
performs the air blow and LED lamps blink*. (*Only
when the indoor unit has that function.)
(4) Touch [
] button to complete indoor unit position
and return to the F2 settings selection screen.
8.2.6. Initialization [No.16]
(1) Select the “16” in F2 settings. Then touch [ ] but-
ton.
(2) To initialize, select “1: Initialize” with [
] or [ ]
button. (If not initializing, select “0:Not initialize”, and
touch [
] button to return to the F2 settings selec-
tion screen.)
(1)
(2)
0 : Not initialize
1 : Initialize
Touch [
] button to reboot the device automatically.
Note
When relocating the remote controller, initialize it.
9. SPECIAL STATE CONFIRMATION
(for Administrator)
(1) With “Monitor Mode” screen displayed, touch and hold
[
] and [ ] button simultaneously for at least
2 seconds.
(2) The special state selection screen appears.
The status icons appear when the product is in a
special state.
(Refer to “4.1. Dimensions and Name of parts” for
more information on these icons.)
(1)
(2)
(3) Select the item number to be set with [ ] or [ ]
button.
Touch [ ] button to switch to the setting screen.
Errors are present
(3)
Refer to the table for the settings of each part number.
For details concerning settings, refer the description of
the setting concerned.
Con rmation Items
Item No. Con rmation item
C2
Displays the con gured economy operation
setting.
0: Disable 1:Enable
C3
Displays the con gured anti freeze operation
setting.
0: Disable 1:Enable
C4
This code appears when an error has oc-
curred.
Touch [
] button. Display the condition of
this product or indoor unit. If an error is pres-
ent in other products than this product, display
of the 2-wire remote controller address can be
switched by [
] or [ ] button.
Refer to “Example error con rmation opera-
tions” described later for more information on
error operation.
(Touch [
] button to return previous
screen.
)
(4) Touch and hold [ ] or [ ] buttons for at least 2
seconds at the same time to return to the “Monitor
Mode” screen.
9373328483-02_IM.indb 119373328483-02_IM.indb 11 11/18/2019 2:04:35 PM11/18/2019 2:04:35 PM