EasyManua.ls Logo

Fujitsu WOYA060LFCA - Page 13

Fujitsu WOYA060LFCA
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Line Function Setting range
or display
Setting
increment
Basic
setting
Time program heating / cooling, circuit 1
500 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
501 1st phase On (start) 00:00... --:-- 10 min 6:00
502 1st phase Off (end) 00:00... --:-- 10 min 22:00
503 2nd phase On (start) 00:00... --:-- 10 min --:--
504 2nd phase Off (end) 00:00... --:-- 10 min --:--
505 3rd phase On (start) 00:00... --:-- 10 min --:--
506 3rd phase Off (end) 00:00... --:-- 10 min --:--
516 Default values, Circuit 1 No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Time program heating / cooling, circuit 2
Only with the 2nd circuit kit option.
520 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
521 1st phase On (start) 00:00... --:-- 10 min 6:00
522 1st phase Off (end) 00:00... --:-- 10 min 22:00
523 2nd phase On (start) 00:00... --:-- 10 min --:--
524 2nd phase Off (end) 00:00... --:-- 10 min --:--
525 3rd phase On (start) 00:00... --:-- 10 min --:--
526 3rd phase Off (end) 00:00... --:-- 10 min --:--
536 Default values, Circuit 2 No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Time program 4 / DHW
560 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
561 1st phase On (start) 00:00... --:-- 10 min 00:00
562 1st phase Off (end) 00:00... --:-- 10 min 05:00
563 2nd phase On (start) 00:00... --:-- 10 min 14:30
564 2nd phase Off (end) 00:00... --:-- 10 min 17:00
565 3rd phase On (start) 00:00... --:-- 10 min --:--
566 3rd phase Off (end) 00:00... --:-- 10 min --:--
576
Default values No, Yes No
Yes + OK: The default values memorised in the regulator replace and cancel the customised heating programs.
Your customised settings are therefore lost.
Holidays, heating circuit 1 (For the Holiday program is active, the heating mode should be on AUT
O).
641 Preselection Period 1 to 8 Period 1
642 Period Start (Day / Month) 01.01... 31.12 1
643 Period End (Day / Month) 01.01... 31.12 1
648 Operating level Frost protection, Reduced Frost
protection
Operation manual "1534 - EN"
- 13 -
Air to Water Heat Pump Split system

Other manuals for Fujitsu WOYA060LFCA

Related product manuals