Air to Water Heat Pump Split system
- 24 -
• Package (High power models)
- application 35 °C
A
+++
A
++
G F E D C B A A
+
< 55% 55% 59% 61% 100% 107% 115% 123% 150% 175%
Models Waterstage ...
HP 11 Single
phase
HP 14 Single
phase
HP 11
3-Phase
HP 14
3-Phase
HP 16
3-Phase
Hydraulic unit reference WSYG140DG6 WSYG140DG6 WSYK160DG9 WSYK160DG9 WSYK160DG9
Seasonal space heating energy efciency of
heat pump
151% 148% 154% 150% 149%
Type of temperature control (* = Outdoor
sensor ; ** = Room unit )
* classe
II
** classe
VI
* classe
II
** classe
VI
* classe
II
** classe
VI
* classe
II
** classe
VI
* classe
II
** classe
VI
Bonus 2% 4% 2% 4% 2% 4% 2% 4% 2% 4%
Seasonal space heating energy efciency of
package under average climate
153% 155% 150% 152% 156% 158% 152% 154% 151% 153%
Energy class of package A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
Seasonal space heating energy efciency of
package under warmer climate
196% 198% 189% 191% 196% 198% 193% 195% 194% 196%
Seasonal space heating energy efciency of
package under colder climate
123% 125% 120% 122% 126% 128% 124% 126% 121% 123%
The energy efciency of the package of products provided for in this che may not correspond to its actual energy efciency once installed in
a building, as the efciency is inuenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
- application 55 °C
A
+++
A
++
G F E D C B A A
+
< 30% 30% 34% 36% 75% 82% 90% 98% 125% 150%
Models Waterstage ...
HP 11 Single
phase
HP 14 Single
phase
HP 11
3-Phase
HP 14
3-Phase
HP 16
3-Phase
Hydraulic unit reference WSYG140DG6 WSYG140DG6 WSYK160DG9 WSYK160DG9 WSYK160DG9
Seasonal space heating energy efciency of
heat pump
109% 113% 112% 117% 117%
Type of temperature control (* = Outdoor
sensor ; ** = Room unit )
* classe
II
** classe
VI
* classe
II
** classe
VI
* classe
II
** classe
VI
* classe
II
** classe
VI
* classe
II
** classe
VI
Bonus 2% 4% 2% 4% 2% 4% 2% 4% 2% 4%
Seasonal space heating energy efciency of
package under average climate
111% 113% 115% 117% 114% 116% 119% 121% 119% 121%
Energy class of package A+ A+ A+ A+ A+ A+ A+ A+ A+ A+
Seasonal space heating energy efciency of
package under warmer climate
119% 121% 130% 132% 125% 127% 135% 137% 141% 143%
Seasonal space heating energy efciency of
package under colder climate
102% 104% 102% 104% 102% 104% 102% 104% 102% 104%
The energy efciency of the package of products provided for in this che may not correspond to its actual energy efciency once installed in
a building, as the efciency is inuenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.