TEMPERATURE AND HUMIDITY
DIGITAL CONTROLLER WITH
SERIAL COMMUNICATION
4.2 - Parameters configuration
- Access the function F01 pressing simultaneously the keys and for 2 seconds until appearing
, releasingafter that. Soon it will appear , and then press (short touch).
- Use the keys and toenter acess code (123) and, when ready press to confirm.
- Use the keys and toaccess the desired function.
-Afterselecting the function, press (short touch) to visualize the value configured for that function.
- Use the keys and to change the value, and when ready, press to memorize the configured
value and return to the menu of functions.
- To leave the menu of functions and return to normal operation, press until appear .
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
4. CONFIGURATIONS
4.1 - Temperature and humidity adjust (SETPOINTS):
- Press for 2 seconds until appears, then release it. The indication and the adjusted
temperature for THERM output will appear.
- Use the keys and tochangethevalue and then press to record it.
- Now andadjustedhumidity for HUMID output will appear.
- Use the keys and tochangethevalue and then press again.
-Then, if the AUX output is set to control (F14 = 0, 1, 2 or 3)it may appear or .
- Use the keys and tochangethevalue for theAUXoutput and then press to record it.
SET
SET
SET
SET
4.4 - Parameters description
MT-530 %uper
1. DESCRIPTION
MT-530 %uper is an instrument that indicates and controls the environment temperature and
humidity, indicated for low and average relative air humidity (from 20 to85%, without condensation) and
temperature of -10 to 70ºC. Its sensors of temperature and humidity are joined in an only bulb, that
reduces the space in wiring of the installation.
The instrument has serial communication for connection with the via Internet.
Product complies with UL Inc. (United States and Canada).
®
SITRAD
2. APPLICATION
3. TECHNICAL SPECIFICATIONS
Humidificators/dehumidificators
Grains drying
Laboratories
Surgical rooms
Climatized cellars
Information technology centers
MT-530 Super - 115 or 230 Vac ±10%(50/60 Hz)
MT-530L Super - 12 or 24 Vac/dc
-10 to 70.0 ºC ±1.5°C (with resolution of 0.1°C)
14 to 158 ºF ±3°F (with resolution of 1°F)
20 to 85%RH ±5%RH(with resolution of 0.1%RH)
5(3)A/250Vac 1/8HP (each output)
71 x 28 x 71 mm
0 to 50°C
32 to 122°F
10 to 90% RH (without condensation)
- Power Supply:
- Control Temperature:
- Control Humidity:
- Load current:
- Dimensions:
- Operation temperature:
- Operation humidity:
DescriptionFun
Access code: 123 (one hundred and twenty-three)
hermostat operation mode (THERM output)
Minimum setpoint allowed to the user (thermostat)
Maximum setpoint allowed to the user (thermostat)
Control differential (hysteresis) of the thermostat
Minimum delay to turn the thermostat output on
Humidistat operation mode (HUMID output)
Minimum setpoint allowed to the user (humidistat)
Maximum setpoint allowed to the user (humidistat)
Control differential (hysteresis) of the humidistat
Minimum delay to turn the humidistat output on
Humidity output (time on)
Humidity output (time off)
Auxiliary output operation mode (AUX)
Minimum setpoint allowed to the user (AUX output)
T
CELSIUS
FAHRENHEIT
Min.
-99
0 - refrig.
-10.0
-10.0
0
0
0 - dehum.
0
0
0
0
0
0
0
0
Max.
999
1 - heat
70.0
70.0
20.0
999
1 - hum.
100
100
20.0
999
999
999
10
100
Unit
-
-
°C
°C
°C
seg.
-
%RH
%RH
%RH
sec.
sec.
sec.
-
-
Standard
-
-10.0
70.0
1.5
0
0 - refrig.
1 - hum.
0
100
5
0
5
5
5
0
Min.
-99
0 - refrig.
14
14
0
0
0 - dehum.
0
0
0
0
0
0
0
0
Max.
999
1 - heat
158
158
36
999
1 - umid.
100
100
20.0
999
999
999
10
100
Unit
-
-
°F
°F
°F
seg.
-
%RH
%RH
%RH
sec.
sec.
sec.
-
-
Standard
-
0 - refrig.
14
158
3
0
1 - hum.
0
100
5
0
5
5
5
0
Maximum setpoint allowed to the user AUX output
Control differential (hysteresis) of the AUX output
Minimum delay to turn the AUX output on
Time base of AUX output timer
AUX output (time on)
AUX output (time off)
Minimum delay to turn the AUX output on (alarm mode)
Acting point of Buzzer by low temperature
Acting point of Buzzer by high temperature
Acting point of Buzzer by low
Acting point of Buzzer by high
Maximum time of the activated THERM output to activate the alarm
Maximum time of the activated HUMID output to activate the alarm
()
Buzzer operation mode
humidity
humidity
Low room temperature alarm
High room temperature alarm
Low room humidity alarm
High room humidity alarm
0
0
0
0
0
0
-10.0
-10.0
0
0
0
0
-10.0
-10.0
0
0
0
0
100
20.0
999
999
999
999
70.0
70.0
100
100
999
1
70.0
70.0
100
100
999
999
-
-
sec.
-
sec.
sec.
°C
°C
%RH
%RH
min.
-
°C
°C
%RH
%RH
min.
min.
100
5
0
0
5
5
-10.0
70.0
0
100
0
1
-10.0
70.0
0
100
0
0
0
0
0
0
0
0
14
14
0
0
0
0
14
14
0
0
0
0
100
20.0
999
999
999
999
158
158
100
100
999
1
158
158
100
100
999
999
100
5
0
0
5
5
14
158
0
100
0
1
14
158
0
100
0
0
-
-
sec.
-
sec.
sec.
°F
°F
%RH
%RH
min.
-
°F
°F
%RH
%RH
min.
min.
Maximum time of the activated AUX output to activate the alarm
Buzzer time on
Buzzer time off
Inhibition time of Buzzer during electrical supply
Display mode
Temperature display offset
Humidity display offset
Network equipment address RS-485
0
0
0
0
0
-5.0
-20.0
0
999
999
999
999
2
5.0
20.0
247
sec.
min.
-
°C
%RH
-
min.
sec.
0
1
1
0
0
0
0
1
0
0
0
0
-9
-20.0
0
0
999
999
999
2
9
20.0
247
999
1
1
0
0
0
0
1
0
sec.
min.
-
°F
%RH
-
min.
sec.
E251415
Ver.02
MT530SP02-01T-12400
TH
E
R
M
HU
M
ID
M
T-530
Super
A
U
X
B
U
Z
Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Full Gauge Controls MT-530 Super and is the answer not in the manual?

Full Gauge Controls MT-530 Super Specifications

General IconGeneral
BrandFull Gauge Controls
ModelMT-530 Super
CategoryController
LanguageEnglish

Related product manuals