This quick start guide will help you install and use the device properly.
For further support please visit www.furrion.com/support.
WHAT’S IN THE BOX
Wa rra nty Man ual
Wa rni ng C ard
Qu ick St art Gu ide
Wa rra nty Ma nual
Wa rni ng C ard
Qu ick Sta rt Gui de
Control Box x 1
QSG x 1
Warranty Manual x 1
NOTE: Product design and packaging may change without notice.
INSTALLATION
WARNING
Risk of Electric Shock
Always verify that the electrical power to the circuit has been
disconnected before performing the installation procedures.
Wire Connection
Familiarize yourself with the controller and wire harnesses.
Wall Thermostat Cable
(4-wire harness)
Furnace Cable (2-wire)
12V DC Power Cable (2-wire)
Freeze Sensor Cable (wire with
copper tip and blue plastic clip)
1. Loosen the cable clamp on top of the control box and remove the
compartment cover. Pass the 115VAC power cord through the cable
clamp hole and make wire connections following the below color
codes:
Black - Hot
White - Neutral
Green/yellow - Ground
2. Fit all cables into the cable
compartment and tuck any excess
wires up out of the way. Re-tighten
the cable clamp, do not over tighten.
Replace the cover.
Cable Clamp
SINGLE ZONE CONTROLLER
MODEL: FACC10SA-BL
FACC10ESSA-BL
QUICK START GUIDE
Question and Answer IconNeed help?

Do you have a question about the Furrion FACC10SA-BL and is the answer not in the manual?

Summary

Whats in the Box

Installation and Wiring

Risk of Electric Shock Warning

Verify electrical power is disconnected before installation. Risk of Electric Shock.

Wire Connection Guide

Instructions for connecting furnace, thermostat, freeze sensor, and power cables.

Mounting the Control Box

Install the control box into the mounting frame and secure with screws.

Summary

Whats in the Box

Installation and Wiring

Risk of Electric Shock Warning

Verify electrical power is disconnected before installation. Risk of Electric Shock.

Wire Connection Guide

Instructions for connecting furnace, thermostat, freeze sensor, and power cables.

Mounting the Control Box

Install the control box into the mounting frame and secure with screws.

Overview

The Furrion Single Zone Controller is a crucial component for managing your RV's climate control system, designed to provide a comfortable and regulated environment within your living space. This quick start guide facilitates the proper installation and initial setup of the device, ensuring you can effectively utilize its features.

Function Description

At its core, the Furrion Single Zone Controller acts as the central hub for your RV's heating and cooling system. It receives inputs from various sensors and your wall thermostat, processing this information to control the furnace and air conditioning unit. The controller is responsible for regulating temperature, managing fan speeds, and ensuring efficient operation of your climate control appliances. It integrates seamlessly with a wall thermostat, allowing you to set desired temperatures and modes of operation (e.g., heat, cool, fan only). The controller also incorporates a freeze sensor input, which can be connected to an optional freeze sensor to protect your plumbing from freezing temperatures, adding an extra layer of safety and peace of mind. Its design aims to simplify the complex wiring of an RV's climate system into a single, manageable unit, making installation and troubleshooting more straightforward.

Usage Features

The primary usage feature of the Furrion Single Zone Controller is its ability to centralize climate control. Once installed, the controller works in conjunction with your wall thermostat to provide intuitive temperature management. You can select your desired temperature, switch between heating and cooling modes, and adjust fan settings directly from the thermostat. The controller interprets these commands and activates the appropriate components, such as the furnace or air conditioner, to achieve and maintain the set conditions. The system is designed for ease of use, allowing occupants to quickly and effectively adjust their indoor climate. The integration with a freeze sensor, if utilized, provides an automatic protective measure, engaging the heating system if temperatures drop to a critical level, thus preventing potential damage to water lines. The controller's robust design ensures reliable operation, contributing to a consistent and comfortable indoor environment regardless of external weather conditions. Its compatibility with standard RV climate control components makes it a versatile choice for many recreational vehicles.

Maintenance Features

While the Furrion Single Zone Controller itself is largely a "set it and forget it" component, its design incorporates features that facilitate maintenance and troubleshooting of the overall climate control system. The clear labeling of wire harnesses and connection points simplifies the process of identifying and addressing potential issues. For instance, the quick start guide emphasizes familiarization with the furnace cable, wall thermostat cable, freeze sensor cable, and 12V DC power cable, each distinctly identified to aid in correct installation and future inspection. The ability to easily access the cable compartment by loosening the cable clamp and removing the cover allows for straightforward inspection of wire connections. This is particularly useful for verifying secure connections and ensuring proper power supply. In the event of a system malfunction, the organized wiring and accessible connection points make it easier for a technician or a knowledgeable owner to diagnose the problem. The guide also highlights the importance of proper wire routing and securing excess wires within the compartment, which not only ensures a tidy installation but also prevents potential damage or disconnections due to vibration during travel. Although the controller itself does not require routine user maintenance, its design contributes significantly to the maintainability of the entire climate control system by making its components and connections easily identifiable and accessible for inspection and repair. The emphasis on verifying electrical power disconnection before any installation or maintenance procedures underscores a critical safety feature, protecting both the user and the device from potential electrical hazards.

Furrion FACC10SA-BL Specifications

General IconGeneral
ModelFACC10SA-BL
Input Voltage12V DC
Operating Temperature32°F to 122°F (0°C to 50°C)
ColorBlack
MaterialPlastic
CompatibilityFurrion appliances
FeaturesDigital display, touch controls
Weight0.18 lbs (0.08 kg)

Related product manuals